Operation
Compaq ES40CSLP Rackmount System Installation/User/Service Guide 3–5
create powerup
entering idle loop
starting console on CPU 3
initialized idle PCB
initializing idle process PID
lowering IPL
CPU 3 speed is 2.00 ns (500MHz)
create powerup
Memory Testing and Configuration Status
Array Size Base Address
--------- ---------- ----------------
0 256Mb 0000000060000000
1 512Mb 0000000040000000
2 256Mb 0000000070000000
3 1024Mb 0000000000000000
2048 MB of System Memory
Testing the System
Testing the Disks (read only)
Testing the Network
initializing GCT/FRU at offset 192000
AlphaServer ES40 Console V5.4-5528, built on Mar 5 1999 at 01:42:13
P00>>>
The primary CPU prints a message indicating that it is running the console. Starting with
this message, the power-up display is printed to any console terminal, regardless of the
state of the console environment variable.
If console is set to graphics, the display from this point to the end is saved in a memory
buffer and printed to the VGA monitor after the PCI buses are sized and the VGA device is
initialized.
The memory size is determined and memory is tested.
The I/O subsystem is probed and I/O devices are reported. I/O adapters are configured.
Device drivers are started.
The console is started on the secondary CPUs. The example shows a four-processor
system.
Various diagnostics are performed.
Systems running Tru64 UNIX or OpenVMS display the SRM console banner and the
prompt, Pnn>>>. The number n indicates the primary processor. In a multiprocessor
system, the prompt could be P00>>>, P01>>>, P02>>>, or P03>>>. From the SRM
prompt, you can boot the Tru64 UNIX or OpenVMS operating system.
Содержание ES40CSLP
Страница 10: ...This is some white text...
Страница 14: ...This is some white text...
Страница 46: ...This is some white text...
Страница 80: ...This is some white text...
Страница 98: ...This is some white text...
Страница 126: ...This is some white text...
Страница 188: ...This is some white text...
Страница 190: ...This is some white text...