Remote System Management
4–10 Compaq ES40CSLP Rackmount System Installation/User/Service Guide
4.7.3 Displaying the System Environment
Use the RMC env command to get a snapshot of the system environment, including the state of
CPUs, fans, and power supplies.
RMC>env
System Hardware Monitor
Temperature (warnings at 45.0
°
C, power-off at 50.0
°
C)
CPU0: 26.0
°
C CPU1: 26.0
°
C CPU2: 27.0
°
C CPU3: 26.0
°
C
Fans RPM
Fan1: 2295 Fan2: 2295 Fan3: 2205
Fan4: 2235 Fan5: 2500
Power Supplies(OK, FAIL, OFF, ‘----‘ means not present)
PS0 : OK PS1 : ---- PS2 : ----
CPU0: OK CPU1: OK CPU2: OK CPU3: OK
CPU CORE voltage
CPU0: +2.192V CPU1: +2.192V CPU2: +2.192V CPU3: +2.192V
CPU IO voltage
CPU0: +1.488V CPU1: +1.488V CPU2: +1.488V CPU3: +1.488V
Bulk voltage
+3.3V Bulk: +3.328V +5V Bulk: +5.076V +12V Bulk: +12.096V
Vterm: +1.824V Cterm: +2.000V -12V Bulk: -12.480V
CPU temperature. In this example four CPUs are present.
Fan RPM. All fans operate as long as the system is powered on. Fans 1 through 4 are the
system fans and Fan 5 is the PCI fan.
The normal power supply mode is either OK (system is powered on) or OFF (system is
powered off or the power supply cord is not plugged in). FAIL indicates a problem with a
supply.
CPU CORE voltage and CPU I/O voltage. In a healthy system, the readings for all CPUs
should be the same.
Bulk power supply voltage.
Содержание ES40CSLP
Страница 10: ...This is some white text...
Страница 14: ...This is some white text...
Страница 46: ...This is some white text...
Страница 80: ...This is some white text...
Страница 98: ...This is some white text...
Страница 126: ...This is some white text...
Страница 188: ...This is some white text...
Страница 190: ...This is some white text...