Removal and Replacement
5–18 Compaq ES40CSLP Rackmount System Installation/User/Service Guide
5.16 System Card-Cage Fan Assembly
Perform the following procedure to remove the system card-cage fan assembly:
1.
Extend the chassis for service (see Section 5.2).
2.
Remove the top cover (see Section 5.4).
3.
Loosen the two captive screws
along the top of the fan assembly (see Figure 5-15).
4.
Lift the fan assembly straight up to disconnect the power connectors
on the bottom of
the chassis and lift the assembly out of the chassis (see Figure 5-15).
5.
Remove the power connector
for the failing fan from the bottom of the fan assembly
bracket (see Figure 5-15).
6.
Remove the four screws
and nuts that secure the failing fan to the fan assembly
bracket and remove the failing fan (see Figure 5-15).
To replace the failing fan and system card-cage fan assembly, refer to Figure 5-15 and reverse
steps 1 through 6 of the removal procedure.
Figure 5-15 Removing and Replacing the CPU Fan Assembly
EA-00087
1
2
3
4
5