background image

 

SPARC Enterprise

T5140 and T5240 Servers

Product Notes

Manual Code C120-E493-17EN
Part No.: 875-4318-26
November 2012, Revision A

Содержание SPARC Enterprise T5140

Страница 1: ...SPARC Enterprise T5140 and T5240 Servers Product Notes Manual Code C120 E493 17EN Part No 875 4318 26 November 2012 Revision A ...

Страница 2: ...mited All SPARC trademarks are used under license and are registered trademarks of SPARC International Inc in the U S and other countries Products bearing SPARC trademarks are based upon architectures developed by Oracle and or its affiliates SPARC64 is a trademark of SPARC International Inc used under license by Fujitsu Microelectronics Inc and Fujitsu Limited Other names may be trademarks of the...

Страница 3: ...es marques SPARC sont utilisées sous licence et sont des marques déposées de SPARC International Inc aux États Unis et dans d autres pays Les produits portant la marque SPARC reposent sur des architectures développées par Oracle et ou ses sociétés affiliées SPARC64 est une marque de SPARC International Inc utilisée sous licence par Fujitsu Microelectronics Inc et Fujitsu Limited Tout autre nom men...

Страница 4: ......

Страница 5: ...e VM Server for SPARC Issues 2 New Information About Documentation Errata 2 2 Important Information About the SPARC Enterprise T5140 and T5240 Servers 3 Notes on DVD Drive and Discs 3 Supported Versions of Solaris OS and System Firmware 4 Solaris OS and Firmware Requirements for Certain Features 5 System Firmware Update 6 Support for Windows 7 and Internet Explorer 8 6 Change and Functional Enhanc...

Страница 6: ...Patches for Option Cards 12 Installing the Fujitsu 4Gbps Fibre Channel Card 12 Notes and Limitations 14 Cryptographic Function 14 Hardware RAID Function 14 Cable Management Arm 16 Express Rail Rackmounting Kit 17 SAS RAID Internal HBA Card 17 SSD Storage 17 Using a SSD as a Boot Device 18 Cache Setting of SSDs 18 Estimated Usable Period of SSDs 18 Preventive Replacement Monitoring Function of SSD ...

Страница 7: ... and T5240 Servers Administration Guide 55 Integrated Lights Out Manager 2 0 User s Guide 56 Integrated Lights Out Manager 2 0 Supplement for SPARC Enterprise T5140 and T5240 Servers 57 Integrated Lights Out Manager ILOM 3 0 CLI Procedures Guide 58 Integrated Lights Out Manager ILOM 3 0 Web Interface Procedures Guide 60 Integrated Lights Out Manager ILOM 3 0 Supplement for SPARC Enterprise T5140 a...

Страница 8: ...2 Fixed in System Firmware 7 2 7 b or Later 93 Fixed in System Firmware 7 2 2 e or Later 100 Fixed in System Firmware 7 1 7 f or Later 107 Fixed in System Firmware 7 1 6 d or Later 113 Fixed in System Firmware 7 1 3 d or Later 114 Fixed in Other Software 118 B Minor Cases 119 Firmware and General Software Events 119 ...

Страница 9: ...he SPARC Enterprise T5140 and T5240 servers http www fujitsu com sparcenterprise manual Downloading Documentation The documentation set of SPARC Enterprise T5140 and T5240 servers is available on the following web site Global Site http www fujitsu com sparcenterprise manual North American Site https download computers us fujitsu com Japanese Site http jp fujitsu com platform server sparcenterprise...

Страница 10: ...cumentation Feedback If you have any comments or requests regarding this document or if you find any unclear statements in the document please state your points specifically on the form at the following web site http www fujitsu com global contact computing sparce_index html ...

Страница 11: ...ous edition was published New Information About Documentation Errata on page 2 This section describes documentation errata that were identified after the previous edition was published Information that was documented in the previous edition is provided in the following locations Chapter 2 contains important information about the T5140 and T5240 servers Chapter 3 describes technical issues Chapter ...

Страница 12: ...Solaris OS Issues There is no technical issue that were identified after the previous edition of this document was published Firmware and General Software Issues There is no technical issue that were identified after the previous edition of this document was published Oracle VM Server for SPARC Issues There is no technical issue that were identified after the previous edition of this document was ...

Страница 13: ...ons of Solaris OS and System Firmware on page 4 Solaris OS and Firmware Requirements for Certain Features on page 5 System Firmware Update on page 6 Preinstalled Software on page 8 Patch Information on page 10 Notes and Limitations on page 14 Notes on DVD Drive and Discs See the Notes on DVD Drive and Discs in SPARC Enterprise on the website below before using the CD DVD discs in the standard DVD ...

Страница 14: ...are that was preinstalled at the factory See Preinstalled Software on page 8 for more information on this additional preinstalled software Note Some optional features require certain versions of the Solaris OS and System Firmware See Solaris OS and Firmware Requirements for Certain Features on page 5 Note When installing the Solaris 10 8 07 OS or Solaris 10 5 08 OS on a server equipped with a USB ...

Страница 15: ...Unit 7 1 6 d Solaris 10 10 08 OS Systems using low voltage LV 1 5V FB DIMMs Follow all of the system memory configuration rules and restrictions defined in the SPARC Enterprise T5140 and T5240 Servers Service Manual 7 1 6 d N A Different FB DIMM capacities on different CPUs 7 1 7 f N A Systems operating with DC power supplies 7 1 7 f Solaris 10 10 08 OS 1 6 GHz processors 7 2 2 e N A ILOM 3 0 firm...

Страница 16: ...al firmware components are updated You cannot update firmware components individually Refer to the SPARC Enterprise T5140 and T5240 Servers Installation Guide for more information about updating the system firmware Support for Windows 7 and Internet Explorer 8 As of System Firmware 7 2 7 the Remote Console feature in ILOM supports Microsoft Windows 7 and Internet Explorer 8 operating system client...

Страница 17: ...Targets history Properties escapechars line_count 0 pause_count 0 start_from end Commands cd show start stop start HOST console Are you sure you want to start HOST console y n y Serial console started To stop type XXXXXX console login load source scp xxxxx xxxxxx XXX XXX XXX XXX mnt1 Firmware_Update Huron 7 2 8 Sun_System_Firmware 7_2_8 SPARC_Enterprise_T5120 T5220 pkg NOTE An upgrade takes severa...

Страница 18: ...ble copy of the root partition including the Solaris OS EIS and applications is installed as an ABE in Slice 3 Firmware update is complete ILOM will now be restarted with the new firmware TABLE 2 3 Preinstalled Software Software Location Function Solaris 10 5 09 Root disk Slice 0 and on Slice 3 in the ABE with patches Operating system Oracle Studio 1 2 U1 developer tools opt sunstudio12 1 C C and ...

Страница 19: ...s MIB must be configured before you can use it For the configuration instructions see the README file located in the Logical Domains MIB installation directory opt ldoms_mib For more information on Oracle VM Server for SPARC go to http www fujitsu com global services computing server sparcent erprise products software ldoms Supported Sun Explorer Utility Version The SPARC Enterprise T5140 and T524...

Страница 20: ...7 OS has been shipped with your server The CD has been provided for recovery purposes in case you chose to install the Solaris 10 8 07 OS Install the patches on the CD if you decide to replace the installed OS with Solaris 10 8 07 Note The patches on the CD include an updated network driver that is required to enable use of the network interfaces on the SPARC Enterprise T5140 and T5240 servers Aft...

Страница 21: ... 08 OS There are no mandatory patches for the Solaris 10 10 08 OS at this time TABLE 2 5 Mandatory Patches for the Solaris 10 8 07 OS Patch ID Description 124235 02 or later libpam so 1 patch 125369 13 or later Fault Manager patch 125416 06 or later UFS utilities patch 125476 02 or later libc_psr_hwcap so 1 patch 126434 05 or later raidctl patch 127127 11 or later Kernel patch 137111 01 or later K...

Страница 22: ...the queried patch or if the dash extension precedes the required version go to Step 2 For example if no version of the 123456 patch or a version with an extension of 15 or earlier is installed you must download and install the new patch 2 Get the necessary patches For the information on how to get the patch releases contact your sales representative 3 Follow the installation instructions provided ...

Страница 23: ...n About the SPARC Enterprise T5140 and T5240 Servers 13 Optional cards Single channel 4Gbps Fibre Channel card SE0X7F11X Dual channel 4Gbps Fibre Channel card SE0X7F12X Required patch FUJITSU PCI Fibre Channel 4 0 914583 04 or later ...

Страница 24: ...g on page 20 Changed Behavior When Operating the Solaris OS With Logical Domains on page 21 Notes on Processor Identification on page 22 Notes on Using 200V Power Supply on page 22 Notes on Using Oracle Solaris 11 OS on page 23 Cryptographic Function When using the cryptographic function install the Solaris 10 9 10 or later If you use the function in the Solaris OS older than Solaris 10 9 10 apply...

Страница 25: ...opies of the data After building a RAID you need to install data newly or restore data from the backup media The RAID build or the synchronization associated with maintenance takes about an hour for a 146GB HDD If there is a system restart during the RAID build or synchronization the build synchronization must be started again from the beginning When the RAID applied the volume size is smaller tha...

Страница 26: ...e raidctl C z To specify the volume capacity Cable Management Arm The SPARC Enterprise T5140 server doesn t support the cable management arm CMA The following restrictions apply when using a CMA on SPARC Enterprise T5240 server The maximum capacity of the CMA is as follows AC input power model 2 AC cables and 6 RJ45 cables DC input power model 6 DC cables and 6 RJ45 cables Optical fiber cables can...

Страница 27: ...drives with the SSDs You can also have both 2 5 inch SAS hard drives and SSDs installed at the same time Note The number of 32GB SATA SSDs which can be installed in T5140 and T5240 servers varies depending on the maximum number of HDDs installed in the servers For details see TABLE 2 8 For instructions on installation and removal of SSDs see the Hot Plugging a Hard Drive described in the SPARC Ent...

Страница 28: ...use replacement may be required before the five year maintenance support period expires Preventive Replacement Monitoring Function of SSD On the ESF Enhanced Support Facility of a certain version or later the preventive replacement monitoring function of SSD is supported Supported versions of software are as follows Supported versions of software ESF Enhanced Support Facility 3 0 to 3 1 and patch ...

Страница 29: ...command or Updating LSI 1068e Controller Firmware to Support SSDs To use SSDs the version of LSI 1068e controller firmware should be 1 27 00 00 or later Depending on the firmware version of your server you may need to update the controller firmware Controller Firmware updates are provided as patch releases For the information on how to get the patch releases contact your sales representative fru_p...

Страница 30: ...d without the RFID tag may temporarily exist FIGURE 2 1 and FIGURE 2 2 show the locations of the RFID tags FIGURE 2 1 SPARC Enterprise T5140 Server Appearance Front View FIGURE 2 2 SPARC Enterprise T5240 Server Appearance Front View FIGURE 2 3 shows the appearance of RFID tag FIGURE 2 3 RFID Tag Appearance RFID Tag RFID Tag Serial Number of the server Asset ID written in the RFID tag ...

Страница 31: ... You can use the Solaris OS halt command to halt the domain Results from Halting or Rebooting the Control Domain The following table shows the expected behavior of halting or rebooting the control primary domain TABLE 2 9 Expected Behavior of Halting or Rebooting the Control Primary Domain Command Other Domain Configured Behavior halt No Host powered off and stays off until powered on at the SP Ye...

Страница 32: ...the same or different sets of virtual processor IDs If domaining is enabled the virtual processor IDs and physical processor IDs are never the same For information about the mapping between virtual and physical CPU numbers see the latest Oracle VM Server for SPARC Administration Guide Processor IDs are simply unique integer values in the domain where the software is running The integer value will ...

Страница 33: ...n logout to from ILOM This message appears because the SMF service ilomconfig interconnect on Oracle Solaris OS accesses ILOM at the startup by using an internal bus Therefore this message can be safely ignored Output example 3192 Mon Nov 7 15 36 43 2011 Audit Log minor host_root Close Session object SP session type value shell success 3191 Mon Nov 7 15 36 42 2011 Audit Log minor root Open Session...

Страница 34: ...24 SPARC Enterprise T5140 and T5240 Servers Product Notes November 2012 ...

Страница 35: ...on page 45 Note For the issues already fixed in the latest version of Solaris OS or System Firmware see Appendix A For the latest version to be supported see Supported Versions of Solaris OS and System Firmware on page 4 Hardware and Mechanical Issues This section describes hardware issues known to exist at this release of the SPARC Enterprise T5140 and T5240 servers Hot Swapping Fan Modules When ...

Страница 36: ...40 does not support half duplex transfer at any of the speeds of 10M 100M 1000M Therefore connect it to a switch hub that supports full duplex transfer False Intermittent SATA Errors Seen on SPARC Enterprise T5140 and T5240 Servers CR 6880299 When booting some systems with SATA DVD devices intermittently log port failure errors in var adm messages The following shows an example of typical error me...

Страница 37: ...s the built in Ethernet port to be unusable If in an environment where an XAUI card is installed the XAUI card becomes faulty not only the XAUI card but also the built in Ethernet port component name MB GBE is disabled during a POST run As a result the built in Ethernet port becomes unusable None For display samples and recovery procedure see A Fault in the XAUI Card Causes the Built in Ethernet P...

Страница 38: ...to proceed normally A diagnostic process will run identifying any faulty hardware 6581309 To use the XVR 300 as a console of the SPARC Enterprise T5xx0 patch 137111 01 or later must be applied If the patch is applied after the OpenBoot PROM OBP variable has been changed to use the XVR 300 as the console console output will revert to the default ILOM console during the Solaris OS boot sequence To u...

Страница 39: ...vice label the letters PBD should say PDB Note This error appears on all SPARC Enterprise T5140 and T5240 servers n a The FM Status Indicator portion of the service label has an erroneous statement Where it says In front of FM on FanBD it should say on top of FM Note This error appears on SPARC Enterprise T5240 server configurations n a The drawing showing the cable management arm being rotated re...

Страница 40: ...All rights reserved OpenBoot 4 28 6 32544 MB memory available Serial XXXXXXXX Ethernet address XX XX XX XX XX XX Host ID XXXXXXXX ERROR The following devices are disabled MB RISER1 XAUI1 The number varies with the layout MB GBE The built in Ethernet port is disabled 0 ok 0 ok show nets No longer displayed because the built in Ethernet port is faulty 0 ok show faulty Target Property Value SP faultm...

Страница 41: ...te the XAUI and GBE components from the asr db blacklist Execution example Alternatively execute the clearasrdb command 3 Disconnect the power cord from the AC outlet 4 Replace the XAUI card 5 Connect the power cord to the AC power source XAUI Card Disables an Onboard Network Port Installing a 10GbE XFP XAUI Adapter Card XAUI card in slot 0 disables on board network port 1 NET1 1 Installing the XA...

Страница 42: ...ber 2012 FIGURE 3 1 XAUI cards and on board network ports TABLE 3 2 Network Ports and Device Names On board network XAUI Slot Device name NET 0 XAUI 1 nxge0 NET 1 XAUI 0 nxge1 PCI 3 PCI 4 PCI 5 PCI 0 XAUI 0 PCI 1 XAUI 1 PCI 2 NET0 NET1 NET2 NET3 2 1 2U device only ...

Страница 43: ...nfirm Whether a USB SATA Drive Unit Is Mounted on page 35 n a While booting SPARC Enterprise T5240 server 16 HDD type mpt driver outputs the following WARNING message Encode devid failed for path target lun SAS address This message shows the failure in the setting of the SES device installed in SPARC Enterprise T5240 server 16 HDD type Because this device is not used you can ignore this message n ...

Страница 44: ...dure is shown below 1 Create an install image on the install server Example This example assumes the DVD medium has been mounted to cdmnt 2 Apply the patches to the install image When installing the Solaris 10 5 08 OS proceed to Step 3 There are no patches you should apply to the install image In case of Solaris 10 8 07 OS Follow the patch application procedure which is stored in the Operating Sys...

Страница 45: ... OS To Confirm Whether a USB SATA Drive Unit Is Mounted For servers shipped after September 2009 the USB SATA DVD drive unit has been mounted Confirm whether a USB SATA DVD drive unit is mounted on your server by using either of the following methods Confirm that the SATA DVD mark appears on the front side of the DVD drive Confirm that specific part numbers are displayed in the output for the foll...

Страница 46: ...ollowing are known firmware and general software issues fru_part_number 5413512 fru_part_number 5413513 Partner_Part_NumberR Partner_Part_Number CF005413512REVxx Partner_Part_NumberR Partner_Part_Number CF005413513REVxx TABLE 3 4 Firmware and General Software Issues CR ID Description Workaround 7110871 When you change SP services https weak_ciphers from disabled to enabled or change it from enable...

Страница 47: ... the firmware PSU monitoring the relevant PSU sensor may sensitively detect the ignorable fluctuation of input power in some cases which results in the relevant message output Therefore the relevant message can be safely ignored 7020694 In SPARC Enterprise T5140 server equipped with System Firmware 7 3 0 c or earlier and power distribution boards with part number CF00511 1604 ILOM identifies the w...

Страница 48: ...vent log may not be in the Solaris OS system log output var adm messages ILOM login event example Nov 7 14 13 03 xxxxxx SC Alert ID 178418 daemon notice Audit minor admin Open Session object session type value shell success Nov 7 14 13 04 xxxxxx SC Alert ID 434268 daemon notice Audit minor admin Close Session object session type value shell success None Perform the ILOM reset operation If not reco...

Страница 49: ...n critical going high reading 1 21 threshold 1 21 Volts Jun 10 06 05 36 IPMI minor ID df0 06 10 2010 06 05 05 Voltage MB V_VCOREL Upper Non critical going low reading 1 16 threshold 1 21 Volts None This is not a problem as far as the value has been restored to normal after detected the message of an excess voltage over the threshold value 6842745 The prtdiag command doesn t show the correct memory...

Страница 50: ...value display example 4369 Mon Jun 29 23 54 28 2009 IPMI Log minor ID e20 06 29 2009 23 54 28 Power Unit SYS VPS Upper Critical going low reading 0 threshold 1215 40 Watts None The value of power consumption shown by SYS VPS is given as an indication For the right value of power consumption see SP powermgmt actual_power Therefore the collected event log can be safely ignored 6823561 In the back up...

Страница 51: ...er off and then power on the system n a In an environment where the keyboard has been connected to the USB port of the server when you restarted Solaris OS OpenBoot PROM may output the Failed to set idle message to the console log Event example usr sbin shutdown i6 y g0 Resetting Failed to set idle SPARC Enterprise T5120 Keyboard Present Copyright c 1998 2011 Oracle and or its affiliates All right...

Страница 52: ...ch 914718 01 or later When it is erroneously detected in SSM apply the Server System Manager patch FJSVapagt patch 914667 05 or later n a The Solaris OS system log may contain the ILOM firmware output message PCM Initialize event detected which is unnecessary Message example SC Alert ID 203687 daemon notice Chassis minor PCM Initialize event detected None No impact on system The output message can...

Страница 53: ...etwork linkup fails Due to this access to ILOM using protocols such as SSH Secure Shell fails Use the Cisco IOS software 12 2 53 SG 12 2 46 SE version or later In case that the 12 2 53 SG 12 2 46 SE version or later cannot be applied you can install other hub switch between the Cisco Catalyst switch and the ALOM ILOM network management port to avoid this event It is already confirmed that this eve...

Страница 54: ...P1 BR1 CH0 D1 MB CMP1 BR1 CH1 D1 0x840000000 1 GB 4 256 MB MB CMP0 BR0 CH0 D0 MB CMP0 BR0 CH1 D0 256 MB MB CMP0 BR1 CH0 D0 MB CMP0 BR1 CH1 D0 256 MB MB CMP0 BR0 CH0 D1 MB CMP0 BR0 CH1 D1 256 MB MB CMP0 BR1 CH0 D1 MB CMP0 BR1 CH1 D1 0x8c0000000 1 GB 4 256 MB MB CMP0 BR0 CH0 D0 MB CMP0 BR0 CH1 D0 256 MB MB CMP0 BR1 CH0 D0 MB CMP0 BR1 CH1 D0 256 MB MB CMP0 BR0 CH0 D1 MB CMP0 BR0 CH1 D1 256 MB MB CMP0...

Страница 55: ...k that the memory size is equal to the mounted memory size Oracle VM Server for SPARC Issues For the issues about Oracle VM Server for SPARC Formerly called Logical Domains of LDoms see the SPARC Enterprise Oracle VM Server for SPARC Important Information ...

Страница 56: ...46 SPARC Enterprise T5140 and T5240 Servers Product Notes November 2012 ...

Страница 57: ...ed Lights Out Manager 2 0 User s Guide on page 56 Integrated Lights Out Manager 2 0 Supplement for SPARC Enterprise T5140 and T5240 Servers on page 57 Integrated Lights Out Manager ILOM 3 0 CLI Procedures Guide on page 58 Integrated Lights Out Manager ILOM 3 0 Web Interface Procedures Guide on page 60 Integrated Lights Out Manager ILOM 3 0 Supplement for SPARC Enterprise T5140 and T5240 Servers on...

Страница 58: ...aintenance This section shows the minimum clearance for service access premised on the standard maintenance work of our company If this minimum clearance cannot be secured contact our field engineer No stepladder is required if this server is installed at the 20U level or lower A stepladder is required if it is installed at the 21U level or higher FIGURE 4 1 shows the minimum clearance for service...

Страница 59: ... each table is incorrect The correct value is as follows Also the maximum operating input current and maximum operating input power indicated in each table were the values at 48 VDC not at 40VDC General Specifications DC Input Models Incorrect Correct Operating input voltage range input voltage tolerance 10 40 75 VDC 48 60 VDC General Specifications DC Input Models Incorrect Correct Maximum operat...

Страница 60: ...s Consequently the idle power value for each configuration is too high by 8 Watts The following table provides the correct values as well as the current incorrect values for each SPARC Enterprise T5140 and T5240 server configuration Configurations Described by Tables Incorrect Idle Input Power Value AC source Correct Idle Input Power Value AC source Incorrect Idle Input Power Value DC source Corre...

Страница 61: ...nge Incorrect Operating Input Power and Heat Dissipation for the 1 4 GHz 16 Disk Configuration The table that describes input power requirements for the SPARC Enterprise T5240 server configuration with 1 4 GHz CPUs and an 16 disk capable backplane states some wrong values for DC input model The following table describes the necessary correction Location of Incorrect Values Incorrect Value Correct ...

Страница 62: ...00 to 240 VAC operating voltage range SPARC Enterprise T5140 and T5240 Servers Installation Guide This manual includes descriptions using the cable management arm CMA however the SPARC Enterprise T5140 server doesn t support the cable management arm Verify Proper Seating of Preinstalled PCIe XAUI Cards The server installation procedure should include instructions for verifying that any preinstalle...

Страница 63: ...Service Manual for information about the PCIe XAUI cards and their risers as well as information about internal cable routing SPARC Enterprise T5140 and T5240 Servers Service Manual Incorrect Data Cable Routing Diagram for T5140 Servers With 4 Disk Backplanes The data cable routing diagram for 4 disk capable backplanes is wrong It shows the cable connected to SAS1 It should be connected to SAS0 Th...

Страница 64: ...in T5240 servers is wrong It shows a single data cable There should be two This is the correct diagram FIGURE 4 2 Internal Cables for Onboard SAS Controller Cards Eight Disk Capable SPARC Enterprise T5240 Servers Fan Module Missing in Data Cable Routing Diagram The cable routing diagram for 8 disk capable backplanes in T5140 systems is missing a fan module in the upper right corner This is the cor...

Страница 65: ...ght Disk Capable SPARC Enterprise T5140 Servers SPARC Enterprise T5140 and T5240 Servers Administration Guide Incorrect Description in Devices and Device Identifiers CR 6712561 DB9 serial port SYS TTYA is indicated in Devices and Device Identifiers on page 38 but the SYS TTYA can not be unconfigured ...

Страница 66: ...e Mirrored Volume The description on page 18 should be modified as the following underlined part If you create a second IM volume before the first IM volume completes its synchronization the first volume s RAID status will indicate SYNC and the second volume s RAID status will indicate DEGRADED Integrated Lights Out Manager 2 0 User s Guide Incorrect ILOM Command Related to IP Address Assignment T...

Страница 67: ...CR 6806789 On the SPARC Enterprise T5140 and T5240 servers ILOM supports a maximum of 5 active sessions including serial Secure Shell SSH and web interface sessions Complement to the Description Regarding Diagnostics Trigger In Specify Diagnostic Trigger Conditions Using the CLI the following description is missing The Solaris OS restart using the Solaris OS shutdown command or the reset on OpenBo...

Страница 68: ...se System Problems on page 88 includes incorrect information Service Snapshot utility does not support the SP data collection using TFTP Variable Option Description URI Any valid target directory location Specifies the URI of the target directory The URI format is as follows protocol username password host directory Where protocol can be one of these transfer methods SFTP TFTP or FTP For example t...

Страница 69: ...on Regarding Diagnostics Trigger In Specify the Diagnostics Trigger the following description is missing The Solaris OS restart using the Solaris OS shutdown command or the reset on OpenBoot PROM never runs diagnostics POST If you want to run POST you need to perform system reset reset SYS or system power off on stop SYS start SYS from ILOM Notes on Downloading System Firmware For the information ...

Страница 70: ...Problems on page 79 includes incorrect information 3 Select the desired Data Set Normal Full or Custom Normal Specifies that ILOM operating system and hardware information is collected Full Specifies that all data is to be collected Selecting Full might reset the system Custom Allows you to choose one or more of the following data sets ILOM Data Hardware Data Basic OS Data Diagnostic Data On the S...

Страница 71: ...s will be retained Incorrect Description about Specifying powercycle Option CR 6881020 When you specify the powercycle option indicated in Specify System Behavior if Restart Fails on page 13 the power on off is not executed but the hardware reset is executed forcibly v Option for flashupdate Command ALOM CMT Command CR 6806268 The description about the v option for flashupdate command is missing i...

Страница 72: ...62 SPARC Enterprise T5140 and T5240 Servers Product Notes November 2012 ...

Страница 73: ...This section explains the hardware and mechanical issues that have been fixed Incorrect Fan Diagrams on Service Label for Eight Disk Capable T5140 Server This error has been fixed for the servers shipped after September 2009 The service label on eight disk capable SPARC Enterprise T5140 server indicates the wrong number of fan modules In various places the label shows six fan modules The correct n...

Страница 74: ... greater than 16 gigabytes Otherwise a memory overflow condition will result TABLE A 1 illustrates the three memory configurations that exhibit this behavior Workaround Assign memory resources in configurations that avoid the combinations shown in TABLE A 1 Bd 1 Fan 0 Bd 1 Fan 1 Bd 1 Fan 2 EMPTY Bd 0 Fan 0 Bd 0 Fan 1 Bd 0 Fan 2 Bd 0 Fan 3 TABLE A 1 Examples of Dual CPU Memory Configurations That C...

Страница 75: ...s 10 5 08 and patch ID 127127 11 or later Configure the number of CPUs in a domain so that the domain has 8 CPUs allocated for each MAU Avoid running SunVTS cryptotest 6619224 Under certain very unusual situations a single logical domain of 65 or more virtual CPUs can hang for an extended period of time Upon recovery the uptime command shows extremely high load averages Note Fixed in Solaris patch...

Страница 76: ... keyboard once to see the output on the virtual console 6555956 Panic can occur during reboot with the message Fatal error has occurred in PCIe root complex The panic occurs only on reboot and has never been observed on the reboot that follows the panic Note Fixed in Solaris 10 5 08 or later Ensure that the system is set to automatically reboot after a panic For information about setting up automa...

Страница 77: ...d section below describes a procedure you can use to recover from this drive type unknown fault mode without the risks associated with the network and media boot methods Workaround The sequence of steps shown in CODE EXAMPLE 1 must be followed exactly as shown To simplify tracking of the procedure the steps are organized into nine sections 1 Determine whether or not the system s boot device is aff...

Страница 78: ...lname set 8 character volume name The jumpstart install process cmd execute cmd then return quit format disk The jumpstart install process AVAILABLE DISK SELECTIONS 0 c0t0d0 drive type unknown problem indication pci 0 pci 0 pci 2 scsi 0 sd 0 0 Specify disk enter its number 0 C quit with ctrl C format quit root host 1 2 Shut the server down then bring it up in single user mode with root filesystem ...

Страница 79: ...ide a working area root mount F tmpfs tmp root cd tmp 4 Capture the boot drive s existing vtoc in a file stored in tmp Use the raw device of the boot device determined at the beginning i e use dev rdsk c t d s not dev dsk c t d s root prtvtoc dev rdsk c0t0d0s0 tmp vtoc boot disk vtoc saved in tmp vtoc 5 Make a copy of the fmthard utility for use in the tmp work area root cp usr sbin fmthard tmp 6 ...

Страница 80: ...fine a partition table current describe the current disk format format and analyze the disk repair repair a defective sector label write label to the disk analyze surface analysis defect defect list management backup search for backup labels verify read and display labels save save new disk partition definitions inquiry show vendor product and revision volname set 8 character volume name The jumps...

Страница 81: ...st management backup search for backup labels verify read and display labels save save new disk partition definitions inquiry show vendor product and revision volname set 8 character volume name The jumpstart install process cmd execute cmd then return quit format partition PARTITION MENU 0 change 0 partition 1 change 1 partition 2 change 2 partition 3 change 3 partition 4 change 4 partition 5 cha...

Страница 82: ...on select define a partition table current describe the current disk format format and analyze the disk repair repair a defective sector label write label to the disk analyze surface analysis defect defect list management backup search for backup labels verify read and display labels save save new disk partition definitions inquiry show vendor product and revision volname set 8 character volume na...

Страница 83: ...e picld SMF service If prtdiag v or prtpicl fails to display status information wait for several minutes and then retry or restart picl Execute prtdiag v about 10 minutes after picl is restarted syncing file systems done rebooting Resetting SPARC Enterprise T5240 No Keyboard Copyright 2009 Sun Microsystems Inc All rights reserved OpenBoot 4 30 4 3968 MB memory available Serial xxxxxxxx Ethernet ad...

Страница 84: ...ge 81 Fixed in System Firmware 7 2 10 or Later on page 82 Fixed in System Firmware 7 2 8 or Later on page 92 Fixed in System Firmware 7 2 7 b or Later on page 93 Fixed in System Firmware 7 2 2 e or Later on page 100 Fixed in System Firmware 7 1 7 f or Later on page 107 Fixed in System Firmware 7 1 6 d or Later on page 113 Fixed in System Firmware 7 1 3 d or Later on page 114 Fixed in Other Softwar...

Страница 85: ... ACTION Call your service provider to determine if your system requires a firmware upgrade Please retain the error log file Note Fixed in System Firmware 7 4 2 or later None The output message can be safely ignored No impact on the system At the Solaris OS startup due to the firmware defect an improper event may be sent to the Solaris OS side In that case Solaris OS fails to interpret such event a...

Страница 86: ...iag v command execution result For details see When the T5240 Server Connected to the 100V Power Supply and Powered On a Message Might Be Displayed in the Solaris OS System Log CR 6972360 on page 78 Note Fixed in System Firmware 7 3 0 c or later None Due to the ILOM firmware bug the input voltage threshold value noncritical of the system which has the 1 6 GHz CPU and of 8 disk configuration contai...

Страница 87: ...oing low reading 0 threshold 2400 RPM IPMI critical ID 9a 08 17 2010 00 39 26 Fan FB0 FM1 F0 TACH Lower Non recoverable going low reading 0 threshold 2400 RPM IPMI critical ID 9a 08 17 2010 00 39 30 Fan FB0 FM2 F1 TACH Lower Non recoverable going low reading 0 threshold 2400 RPM Fan Status Fans Speeds Revolution Per Minute Sensor Status Speed Warn Low SYS FANBD0 FM0 F0 TACH FAILED 0 4000 2400 SYS ...

Страница 88: ...FM1 SP detected fault TACH at SYS FANBD0 FM1 F0 has reached low non recoverable threshold 4 SYS FANBD0 FM2 SP detected fault TACH at SYS FANBD0 FM2 F1 has reached low non recoverable threshold Jul 23 15 18 43 xxxxxxx SC Alert ID 156290 daemon notice SC unretrieved msg IPMI minor ID 2561 07 23 2010 05 53 31 Voltage PS1 V_IN_MAIN Lower Non critical going low reading 103 20 threshold 163 20 Volts Jul...

Страница 89: ...wer cord and while POST is running the SYS XXXXX prom is unreadable or corrupted message may appear and stop at ok prompt Message example Voltage sensors Location Sensor Status SYS MB V_ 3V3_STBY ok SYS MB V_ 3V3_MAIN ok SYS MB V_ 12V0_MAIN ok SYS MB V_VDDIO ok SYS MB V_VCOREL ok SYS MB V_VCORER ok SYS MB V_ 1V5_IO ok SYS MB V_VMEML ok SYS MB V_VMEMR ok SYS MB V_VBAT ok SYS PS0 V_IN_MAIN warning 1...

Страница 90: ... 0 Test Memory Done 0 0 0 Setup POST Mailbox Done 0 0 0 Master CPU Tests Basic Done 0 0 0 Init MMU Fault critical SP detected fault at time Mon Jan 18 08 45 10 2010 SYS PADCRD prom is unreadable or corrupted 0 0 0 NCU Setup and PIU link train Done 0 0 0 L2 Tests Done 0 0 0 Extended CPU Tests Done 0 0 0 Scrub Memory Done 0 0 0 SPU CWQ Tests Done 0 0 0 MAU Tests Done 0 0 0 Network Interface Unit Tes...

Страница 91: ...r Later CR ID Description Workaround 6948710 With System Firmware 7 2 7 b or later messages referring to hot insertions removals of devices including a nonexistent device may be displayed intermittently during the system startup and the system running Message example of a nonexistent device Chassis major Hot insertion of SYS MB RISER1 XAUI1 Chassis major Hot removal of SYS MB RISER1 XAUI1 Message ...

Страница 92: ...m the ILOM reset operation to recover The ILOM reset operation has no impact on the system For details see After a Faulty PSU Replaced on the T5140 Server the Fault Indication May Not Be Cleared CR 6967929 on page 84 6948680 When you change the system diagnostics settings HOST diag from Remote Control Diagnostics tab in the ILOM Web interface the value of Trigger fails to be set with a pop up mess...

Страница 93: ... of Link Card Connected to PCI Box Is Falsely Displayed CR 6942238 on page 87 Note Fixed in System Firmware 7 2 10 or later None This can be safely ignored To check the fibre channel card mount use IO Devices of the prtdiag command of Solaris OS For details see Slot Number of Link Card Connected to PCI Box Is Falsely Displayed CR 6942238 on page 87 6939213 After updated to System Firmware 7 2 8 wh...

Страница 94: ... Fixed in System Firmware 7 2 10 or later None When this event occurred perform the ILOM reset operation If not recovered shut down the system and then remove and insert the power cord ILOM reset operation example Log in to ILOM and execute the following command Using ILOM command mode reset SP Are you sure you want to reset SP y n y Using ALOM CMT compatible shell sc resetsc Are you sure you want...

Страница 95: ...ompatible shell Fujitsu 4Gbps Fibre Channel Card Is Falsely Recognized as F20 Card CR 6947945 This issue is resolved by updating the system firmware to 7 2 10 or later sc showfaults Last POST Run Mon May 31 05 57 59 2010 Post Status Passed all devices ID FRU Fault 1 SYS PS0 SP detected fault Fan fault at PS0 asserted sc sc showenvironment partial excerpt System Indicator Status SYS LOCATE SYS SERV...

Страница 96: ...mple in time of failure Configuration PCIE 0 Fibre Channel card PCIE 1 void PCIE 2 void PCIE 3 void PCIE 4 void PCIE 5 void The ILOM CLI interface output example FRU Status in the prtdiag v command output Workaround None This can be safely ignored To check the fibre channel card mount use IO Devices of the prtdiag command of Solaris OS The prtdiag command execution result SYS MB RISER1 PCIE1 F20CA...

Страница 97: ... below is an event example in time of failure Configuration PCIE 0 void PCIE 1 void PCIE 2 void PCIE 3 void PCIE 4 void PCIE 5 Link Card The ILOM CLI interface output example LEDs and FRU Status in the prtdiag v command output MB FIBRE fibre channel pci 500 pci 0 pci 9 fibre channel SYS MB RISER0 PCIE3 LINK Properties type Link Card fru_description Copper Link Card fru_manufacturer Celestica fru_v...

Страница 98: ... pci c pci 0 pci 1 pci 0 pci 0 pci 0 1 FJSV e4ta 6 PCIE5 PCIE FJSV e4ta fjgi Broadcom BCM5704C pci 500 pci 0 pci c pci 0 pci 1 pci 0 pci 0 pci 0 1 FJSV e4ta 6 1 PCIE5 PCIE FJSV e2ta fjgi Broadcom BCM5715C pci 500 pci 0 pci c pci 0 pci 1 pci 0 pci 9 pci 0 FJSV e2ta 4 PCIE5 PCIE FJSV e2ta fjgi Broadcom BCM5715C pci 500 pci 0 pci c pci 0 pci 1 pci 0 pci 9 pci 0 FJSV e2ta 4 1 PCIE5 PCIE FJSV e4tb fjgi...

Страница 99: ... pci 0 pci 9 pci 0 pci 1 pci 0 1 FJSV e4ta 6 PCIE5 PCIE FJSV e4ta fjgi Broadcom BCM5704C pci 500 pci 0 pci c pci 0 pci 9 pci 0 pci 1 pci 0 1 FJSV e4ta 6 1 PCIE5 PCIE FJSV e2ta fjgi Broadcom BCM5715C pci 500 pci 0 pci c pci 0 pci 9 pci 0 pci 9 pci 0 FJSV e2ta 4 PCIE5 PCIE FJSV e2ta fjgi Broadcom BCM5715C pci 500 pci 0 pci c pci 0 pci 9 pci 0 pci 9 pci 0 FJSV e2ta 4 1 314 Tue Apr 13 14 31 07 2010 IP...

Страница 100: ..._MAIN lower_noncritical_threshold of 0 000 Volts or N A The displayed value during normal operation is 163 200 Volts Therefore the power input sensor cannot detect critical input power problems in the device Example of display of 0 000 Volts 301 Tue Apr 13 14 31 07 2010 IPMI Log minor ID 25 04 13 2010 14 30 43 Entity Presence MB P0 MR0 P Device Absent 278 Tue Apr 13 14 31 06 2010 IPMI Log minor ID...

Страница 101: ...N_MAIN ipmi_name PS0 V_IN_MAIN SYS PS0 V_IN_MAIN class Threshold Sensor SYS PS0 V_IN_MAIN value 196 800 Volts SYS PS0 V_IN_MAIN upper_nonrecov_thresho N A ld SYS PS0 V_IN_MAIN upper_critical_thresho N A ld SYS PS0 V_IN_MAIN upper_noncritical_thre N A shold SYS PS0 V_IN_MAIN lower_noncritical_thre 163 200 Volts shold SYS PS0 V_IN_MAIN lower_critical_thresho N A ld SYS PS0 V_IN_MAIN lower_nonrecov_t...

Страница 102: ...rmware 7 2 8 or Later CR ID Description Workaround 6919764 In System Firmware 7 2 7 b after the power on of a system mounted with the Fujitsu 4Gbps Fibre Channel card the message F20CARD prom is unreadable or corrupted may appear in the ILOM event log and the Service Required LED may turn on Solaris OS completes the startup normally and the fibre channel card is normally recognized on Solaris OS F...

Страница 103: ...ystem Firmware 7 2 7 b or later If only the SCC module fails replace the SCC module together with the motherboard After replacing these components restore the backed up contents 6856163 If the service processor is initialized with the LAN cable disconnected from the ILOM network port the ILOM firmware serial console window displays an error message indicating a failure to start an ILOM internal pr...

Страница 104: ...r property SP system_identifier is its default value none the value of the system description property SP system_description will be stored in the backup file Example of erroneously stored data entry property SP system_identifier property value SPARC Enterprise T5140 ILOM v3 0 3 20 e r46064 value entry Note Fixed in System Firmware 7 2 7 b or later None Delete the entry of SP system_identifier in ...

Страница 105: ...n indicated by a command such as showfaults 6821325 In the output from the prtdiag command warnings may be displayed for input voltage sensors V_IN_MAIN on power supply units For examples see In the Output from the prtdiag Command Warnings May Be Displayed CR 6821325 on page 99 Note Fixed in System Firmware 7 2 7 b or later None Ignore this issue because it is only a display error 6816507 After mo...

Страница 106: ...rmware patch after the completion of firmware download system power off process does not start automatically Execution example sysfwdownload u Sun_System_Firmware 7_1_3_d SPARC_Enterprise_T5120 T5220 pkg WARNING Host will be powered down for automatic firmware update when download is completed Do you want to continue yes no yes 7 15 23 31 39 Download completed successfully After this the server po...

Страница 107: ...3 This issue is resolved by updating the system firmware to 7 2 7 b or later If the service processor is initialized 1 with the LAN cable disconnected from the ILOM network port the ILOM firmware serial console window displays an error message 2 indicating a failure to start an ILOM internal process As a result ILOM fails to start 1 Service processor initialization has the following meaning Using ...

Страница 108: ... restore normal system operation by using the following procedure 1 Disconnect the power cord 2 Connect the LAN cable to the ILOM network port 3 Connect the power cord 4 Verify that the ILOM network port is linked up sc setdefaults sc resetsc SUNSP BEL07482AU login root Password Waiting for daemons to initialize Timed out waiting for daemons to start 2 sccd daemon has shutdown 2 Integrated Lights ...

Страница 109: ... and the status of fan temperature power sensor and so on In the Output from the prtdiag Command Warnings May Be Displayed CR 6821325 This issue is resolved by updating the system firmware to 7 2 7 b or later In the output from the prtdiag command warnings may be displayed for input voltage sensors V_IN_MAIN on power supply units Environmental Status No data output FRU Status Location Name Status ...

Страница 110: ...e showlogs command IPMI minor ID 20a 03 11 2009 02 31 48 Current PS0 CUR_FAULT State Asserted IPMI minor ID 20b 03 11 2009 02 31 51 Temperature PS0 TEMP_FAULT State Asserted IPMI minor ID 20c 03 11 2009 02 31 54 Current PS0 CUR_FAULT State Deasserted IPMI minor ID 20d 03 11 2009 02 31 57 Temperature PS0 TEMP_FAULT State Deasserted Note Fixed in System Firmware 7 2 2 e or later None If the Service ...

Страница 111: ...mand set SYS IOX XX PSX clear_fault_action true to clear the error information 6782508 The SP powermgmt policy property has been disabled Note Fixed in System Firmware 7 2 2 e or later To SP powermgmt policy the following properties have become available Performance The system is allowed to use all the power that is available Elastic The system power usage is adapted to the current utilization lev...

Страница 112: ...wer cord removal and insertion when you power on the server check the OpenBoot PROM environmental variable Especially in case the OpenBoot PROM environmental variable use nvramrc has been set to true it is necessary in advance of starting the Solaris OS to see the ok prompt and check that use nvramrc has been set to true and then execute the boot command Confirmation example 0 ok printenv use nvra...

Страница 113: ... will be disconnected and an error message might be output to the console For an example of the message see MCU Might Be Disconnected in DIMM Module Failure CR 6656116 on page 106 Note Fixed in System Firmware 7 2 2 e or later Identify and replace the faulty DIMM module 6586305 Using the SP setdate command ALOM compatibility shell after having configured non default logical domains can cause the d...

Страница 114: ...is correct Example of showpower v command execution This is incorrect The SYS PS0 value is correct Workaround None Ignore this issue because it is only a display error Sun Explorer May Fail to Collect the ILOM Data Tx000 CR 6718841 This issue is resolved by updating the system firmware to 7 2 2 e or later sc showpower v Power Supplies INPUT OUTPUT Power Power Supply Status W W SYS PS0 OK 172 8 123...

Страница 115: ...he Integrated Lights Out Manager ILOM 3 0 Concepts Guide refer to the Collect SP Data to Diagnose System Problems section to collect the SP data information In ILOM 2 x or earlier Collect the ILOM and ALOM data and supply it to service engineers along with the Sun Explorer output a Collect the following data on ILOM show SP users show SP users admin show HOST b Create an ALOM compatible user and c...

Страница 116: ...reset on SP Jun 04 06 11 22 Chassis major Jun 4 06 11 22 ERROR MCU2 initialization failed DRAM init disabled Jun 04 06 11 23 Fault critical SP detected fault at time Wed Jun 4 06 11 23 2008 SYS MB CMP0 MCU2 Forced fail DRAM init Jun 04 06 11 24 Chassis major Jun 4 06 11 24 ERROR MB CMP0 MCU3 unused because MB CMP0 MCU2 is not configured Jun 04 06 11 24 Chassis major Jun 4 06 11 24 ERROR MB CMP0 L2...

Страница 117: ...red on can cause the host to crash Note Fixed in System Firmware 7 1 7 f or later Do not reset the service processor while the system is powered on If you encounter this issue power cycle the server 6731227 Two circumstances can cause a logical domain to hang when reassigning I O branches from the primary domain control domain to a guest domain I O domain For details see A Logical Domain May Hang ...

Страница 118: ...t MCU is faulty but the motherboard memory mezzanine kit or memory may be faulty If the serial management port SER MGT is used at the time of host activation the following message is displayed Displayed message example Chassis major Jul 4 10 11 10 ERROR CMP1 MCU0 CH0 D2 Failed IBIST MCU disabled Fault critical SP detected fault at time Fri Jul 4 10 11 12 2008 SYS MB CMP1 MCU0 Forced fail IBIST Not...

Страница 119: ...configuration 3 ldm add io pci 500 primary Add pci 500 back to the configuration 4 ldm add config config_name Save new configuration to SP 5 clean shutdown and power cycle Case 2 If the you assign I O branches to guest domains in any order except in numerical order one or more of the guest domains will be unable to start For example the following actions performed in the sequence shown might lead ...

Страница 120: ...ee guests Do the following 1 ldm add io pci 500 guestB 2 ldm add io pci 600 guestA 3 ldm add io pci 700 guestC Example 2 The primary domain is using pci 500 onboard 1Gb sec and10Gb sec network slots PCIE4 PCIE5 XAUI0 XAUI1 and you want to assign pci 400 pci 600 and pci 700 to three guests Do the following 1 ldm add io pci 400 guestB 2 ldm add io pci 600 guestA 3 ldm add io pci 700 guestC If you en...

Страница 121: ...P1 MEM1 were only 16 Gbytes This situation might happen in two different situations each situation has its own recovery procedure Case 1 POST has determined that multiple FBDIMMS have failed on T5140 and T5240 servers with 64 8 Gbyte FB DIMMS If POST takes a FB DIMM offline you must replace it immediately If replacing the failed FB DIMM is not immediately possible or desired you must disable the c...

Страница 122: ...he following device was disabled SYS MB MEM0 CMP0 BR0 CH0 D1 Then disable the following additional devices SYS MB MEM1 CMP1 BR0 CH0 D1 SYS MB MEM2 CMP2 BR0 CH0 D1 SYS MB MEM3 CMP3 BR0 CH0 D1 Case 2 You have added new FB DIMM modules to T5140 and T5240 servers and have configured one of the CMP memory module pairs with significantly more memory than the other modules Reallocate the FB DIMMs across ...

Страница 123: ...nent_state enabled For ALOM 1 Delete the CPU strand component from the asr db blacklist enablecomponent SYS MB CMP1 P0 6728569 When you logged in to ILOM from SSH client it takes 20 to 30 seconds or more before the login completes before the ILOM prompt or SC displayed It normally takes about 10 seconds Note Fixed in System Firmware 7 1 6 d or later Power off the system disconnect the power cord w...

Страница 124: ...bled One symptom is an erroneous value reported by prtdiag for CPU frequency 1162MHz instead of 1167MHz Another symptom of these discrepancies is the logging of numerous time reset messages by NTP Note Fixed in System Firmware 7 1 3 d or later The NTP time reset messages can safely be ignored 6660496 Fault Management diagnosis of I O devices and CPU devices in a Logical Domains environment might n...

Страница 125: ...hile the host machine is powered on If the service processor is reset while the system power is active the machine must be power cycled before the LDoms Manager can start properly Note Fixed in System Firmware 7 1 3 d or later 6652046 POST error messages for some types of XAUI test failures can be misleading The POST error messages can identify the correct port while reporting the wrong slot numbe...

Страница 126: ...e OpenBoot PROM ok prompt when the NUL character is entered no word completion will be performed If the host has booted the Solaris OS when the NUL character is entered the host drops to the minimenu For example c ontinue s ync r eboot h alt Note Fixed in System Firmware 7 1 3 d or later Use Control for command completion when at the ok prompt If the host drops to the minimenu enter c to resume no...

Страница 127: ...splayed by the showfaults command and the PSH console message displayed on the host 6637996 The value of OpenBoot PROM variable pci mem64 should be set to true the default with one exception If bootmode is set to reset_nvram the value will be false upon first poweron Note that on the second poweron the bootmode will reset to normal and the default value of pci mem64 will return to true Note Fixed ...

Страница 128: ...to the desired value 6612947 Usually after a power failure the server resets and reboots automatically When the power failure is very brief the host might hang while the SP continues to operate as though the host was still functioning The entire system can appear to be hung Note Fixed in System Firmware 7 1 3 d or later Log into the service processor and reset the system 6610641 When unconfiguring...

Страница 129: ...d System Firmware 7 2 8 or later when you restore the ILOM setting and downgrade the firmware version to earlier than 7 2 8 the log output may be limited to part of the past ILOM event log For details see After Downgraded the System Firmware the Log Output May Be Limited to Part of the Past ILOM Event Log CR 6952927 on page 122 None The newly generated ILOM event log is normally collected 6837115 ...

Страница 130: ...ples see For DC Input Power Models PS0 AC_POK Is Displayed CR 6815369 on page 124 None 6752910 After a host power on instruction is executed from ILOM the POST may not start and processing may not go to Solaris OS boot processing or the ok prompt for OpenBoot PROM For details see After a Host Power On Instruction Is Executed from ILOM the POST May Not Start and Processing May Not Go to OS Boot Pro...

Страница 131: ...change the properties displayed below at power on so as not to change the system time directly or enable NTP services show SP clock SP clock Targets Properties datetime Wed Dec 3 06 22 48 2008 usentpserver disabled Commands cd set show 6723410 If you repeat in sequence a login to the service processor executing a command and logging out logout may fail If this problem occurs terminate the login se...

Страница 132: ...system For CPU cores that have been disabled their thread status is displayed as Unknown in the Browser Interface and none in the DMTF CLP The ALOM CMT CLI showcomponent command lists components present in the system as well as components that are not present such as DIMMS and XAUI cards that could be added to the system already enabled The showcomponent command does not list any threads for CPU c...

Страница 133: ...operties Commands cd show ID Date Time Class Type Severity 4463 Mon Apr 5 06 51 54 2010 Audit Log minor root Open Session object session type value shell success 4462 Mon Apr 5 06 39 11 2010 Audit Log major Upgrade Succeeded 4461 Mon Apr 5 06 32 18 2010 Audit Log minor root Set object config load_uri value ftp root 192 9 2 00 254 export LOG ilom_backup LE4 3_728 config success set SP network pendi...

Страница 134: ...connected When the DC power cord is reconnected show SP network d properties SP network Properties commitpending Cannot show property dhcp_server_ip none ipaddress none ipdiscovery none ipgateway none ipnetmask none macaddress none pendingipaddress 192 9 200 33 pendingipdiscovery static pendingipgateway none pendingipnetmask 255 255 255 0 state disabled IPMI minor ID 1cec 02 06 2009 04 00 26 Power...

Страница 135: ...console Entering the escape character restores the ILOM prompt The result of the Domain Status may vary No power on log item has been recorded in the event log showplatform command and showlogs command domain status reference example PS0 DC_POK State Asserted IPMI minor ID 1cf1 02 06 2009 04 00 59 Power Supply PS0 FAIL State Deasserted start SYS start SP console Are you sure you want to start SP c...

Страница 136: ...s been powered off There is no Host has been powered on log entry after this sc shutdown i6 g0 y Shutdown started Tue Apr 13 16 10 09 JST 2010 Changing to init state 6 please wait Broadcast Message from root console on xxxxxxx Tue Apr 13 16 10 09 THE SYSTEM maramba1 IS BEING SHUT DOWN NOW Log off now or risk your files being damaged svc startd The system is coming down Please wait svc startd 101 s...

Страница 137: ...m and the USB device and can be safely ignored SunOS Release 5 10 Version Generic_141444 09 64 bit Copyright 1983 2009 Sun Microsystems Inc All rights reserved Use is subject to license terms Hostname xxxxxxxx dev rdsk c1t0d0s7 is clean Reading ZFS config done xxxxxxxx console login ...

Страница 138: ...128 SPARC Enterprise T5140 and T5240 Servers Product Notes November 2012 ...

Отзывы: