106
SPARC Enterprise T5140 and T5240 Servers Product Notes • November 2012
consolehistory -v
showcomponent
showdate
showenvironment
showfaults -v
showfru
showhost
showkeyswitch
showlogs -v -g 0 -p p
shownetwork
showplatform -v
showsc
showsc version -v
showusers
c. Reset ILOM.
MCU Might Be Disconnected in DIMM Module Failure (CR
6656116)
This issue is resolved by updating the system firmware to 7.2.2.e or later.
If the DIMM module fails, the MCU will be disconnected, and the following message might
be output to the console.
Message Example:
->
reset /SP
Are you sure you want to reset /SP (y/n)?
y
Performing hard reset on /SP
Jun 04 06:11:22: Chassis |major : "Jun 4 06:11:22 ERROR: MCU2
initialization failed: DRAM init, disabled"
Jun 04 06:11:23: Fault |critical: "SP detected fault at time Wed
Jun 4 06:11:23 2008. /SYS/MB/CMP0/MCU2 Forced fail (DRAM init)"
Jun 04 06:11:24: Chassis |major : "Jun 4 06:11:24 ERROR:
MB/CMP0/MCU3 unused because MB/CMP0/MCU2 is not configured"
Jun 04 06:11:24: Chassis |major : "Jun 4 06:11:24 ERROR:
MB/CMP0/L2_BANK4, MB/CMP0/L2_BANK5 unused because MB/CMP0/MCU2 is
not configured"
Jun 04 06:11:24: Chassis |major : "Jun 4 06:11:24 ERROR:
MB/CMP0/L2_BANK6, MB/CMP0/L2_BANK7 unused because MB/CMP0/MCU3 is
not configured"
Jun 04 06:11:24: Chassis |major : "Jun 4 06:11:24 ERROR: Degraded
configuration: system operating at reduced capacity"
Jun 04 06:11:24: Chassis |major : "Jun 4 06:11:24 ERROR: System
DRAM Available: 002048 MB"
Содержание SPARC Enterprise T5140
Страница 4: ......
Страница 34: ...24 SPARC Enterprise T5140 and T5240 Servers Product Notes November 2012 ...
Страница 56: ...46 SPARC Enterprise T5140 and T5240 Servers Product Notes November 2012 ...
Страница 72: ...62 SPARC Enterprise T5140 and T5240 Servers Product Notes November 2012 ...
Страница 138: ...128 SPARC Enterprise T5140 and T5240 Servers Product Notes November 2012 ...