SPARC Enterprise T5140 and T5240 Servers Product Notes • November 2012
[Using ILOM command mode]
[Using ALOM CMT compatible shell]
Type one of the following commands to display a list of enabled and disabled devices:
[Using ILOM command mode]
[Using ALOM CMT compatible shell]
For each FB-DIMM device that is disabled, disable the corresponding FB-DIMM associated
with the other CMP/memory module units. For example, if the following device was
disabled:
/SYS/MB/MEM0/CMP0/BR0/CH0/D1
Then, disable the following additional devices:
/SYS/MB/MEM1/CMP1/BR0/CH0/D1
/SYS/MB/MEM2/CMP2/BR0/CH0/D1
/SYS/MB/MEM3/CMP3/BR0/CH0/D1
■
Case 2 - You have added new FB-DIMM modules to T5140 and T5240 servers and have
configured one of the CMP/memory module pairs with significantly more memory than
the other modules
Reallocate the FB-DIMMs across the CMP/memory modules to keep the total number and
types of FB-DIMMs the same on each CMP/memory module pair.
->
set /SYS/component component_state=disabled
sc>
disablecomponent asr-key
->
show components
sc>
showcomponent