Appendix A
Fixed Issues
97
Also, the following type of log is output (*) to the ILOM serial console window at the
occurrence of the failure. sccd fails to start at ILOM startup:
Example of output to ILOM serial console at failure occurrence:
Be sure to back up the service processor settings before replacing the SCC module.
Workaround:
If only the SCC module fails, replace the SCC module together with the
motherboard.
After replacing these components, restore the backed up contents.
When the Service Processor Is Initialized, ILOM May Fails to
Start with an Error Message Displayed (CR 6856163)
This issue is resolved by updating the system firmware to 7.2.7.b or later.
If the service processor is initialized (*1) with the LAN cable disconnected from the ILOM
network port, the ILOM firmware serial console window displays an error message (*2)
indicating a failure to start an ILOM internal process. As a result, ILOM fails to start.
(*1) Service processor initialization has the following meaning:
[Using ILOM command mode]
SUNSP-BEL07482AU login:
root
Password:
Waiting for daemons to initialize...
Timed out waiting for daemons to start
<-- (*)
sccd daemon has shutdown
<-- (*)
Integrated Lights Out Manager
Version 3.0.3.20.e
Copyright 2009 Sun Microsystems, Inc. All rights reserved.
Use is subject to license terms.
Warning: password is set to factory default.
->
->
set /SP reset_to_defaults=all
or
factory
->
reset /SP
Содержание SPARC Enterprise T5140
Страница 4: ......
Страница 34: ...24 SPARC Enterprise T5140 and T5240 Servers Product Notes November 2012 ...
Страница 56: ...46 SPARC Enterprise T5140 and T5240 Servers Product Notes November 2012 ...
Страница 72: ...62 SPARC Enterprise T5140 and T5240 Servers Product Notes November 2012 ...
Страница 138: ...128 SPARC Enterprise T5140 and T5240 Servers Product Notes November 2012 ...