7-18
Cisco TelePresence System Administrator Guide
OL-21845-01
Chapter 7 Troubleshooting the CTS 1100
Managing CTS 1100 Hardware Setup
Troubleshooting Cameras
Use the information in
Table 7-3
to troubleshoot problems with cameras.
Related Information
For more information about setting up and testing cameras, see the
Cisco TelePresence System 1100
Assembly, Use & Care, and Field Replacement Unit Guide
.
For more system troubleshooting information, see the
Cisco TelePresence System Troubleshooting
Guide
on Cisco.com.
Table 7-3
Troubleshooting Cameras
Problem
Possible Cause
Action
Camera image appears on the
wrong display.
Cables are plugged into the
wrong connector ports.
•
Check that the cables from each camera are
plugged into the correct connector on its respective
codec.
•
Two connections are made for the camera, an
RJ-45 cable plugs into the large connector and a
video-to-DVI-I cable plugs into the small
connector. Connect them as follows:
–
Plug the center camera into the primary codec.
–
Plug the participant’s left camera into the left
secondary codec.
–
Plug the participant’s right camera into the
right secondary codec.
Image not positioned correctly.
Camera is not aligned correctly.
Adjust and focus the camera using the targets.
Image colors are incorrect.
•
Video cable is only partially
connected.
•
Color settings are not
correct.
•
Tug on the plug to see if it is fully plugged in.
•
See the
Routing Power and Signal Cables
section
in the
Cisco TelePresence System 1100 Assembly,
Use & Care, and Field Replacement Unit Guide
.
No image.
•
Lens cap is in place.
•
Camera is not plugged in or
is plugged in incorrectly.
•
Remove the lens cap.
•
Check power connections and switches on each
display.
•
Verify that the video and Ethernet cables from each
camera are plugged into the correct connectors on
their respective codecs.
Camera or display is broken.
Contact Cisco technical support if you are certain that
the cabling is correct, power is applied, and a display
and camera test has been run, but no image is seen on
the display.
Camera top-to-bottom switching
discontinuity.
Image may take up to 1 second to
normalize when the camera
switches to the active speaker.
This is normal DSP behavior. Can also occur during
audio addin. Contact Cisco technical support.
Содержание CTS 1000 - TelePresence System 1000 Video Conferencing
Страница 22: ...viii Cisco TelePresence System Administration Guide OL 21845 01 What s in This Guide ...
Страница 122: ...4 50 Cisco TelePresence System Administration Guide OL 21845 01 Chapter 4 Troubleshooting the CTS 500 Where to Go Next ...
Страница 170: ...6 40 Cisco TelePresence System Administration Guide OL 21845 01 Chapter 6 Troubleshooting the CTS 1000 Where to Go Next ...
Страница 212: ...7 42 Cisco TelePresence System Administrator Guide OL 21845 01 Chapter 7 Troubleshooting the CTS 1100 Where to Go Next ...