23-7
Catalyst 6500 Series Switch Software Configuration Guide—Release 8.7
OL-8978-04
Chapter 23 Configuring Redundancy
Configuring Redundant Supervisor Engines on the Switch
To force a switchover to the standby supervisor engine, perform this task in privileged mode:
In addition, you can also force a switchover to the standby supervisor engine by setting the
CISCO-STACK-MIB moduleAction variable to reset(2) on the active supervisor engine. When the
switchover occurs, the system sends a standard SNMP warm-start trap to the configured trap receivers.
This example shows the console output on the active supervisor engine when you force a switchover
from the active to the standby supervisor engine:
Console> (enable)
reset 1
This command will force a switch-over to the standby Supervisor module.
Do you want to continue (y/n) [n]?
y
Console> (enable) 12/07/1998,17:04:39:SYS-5:Module 1 reset from Console//
System Bootstrap, Version 3.1(2)
Copyright (c) 1994-1997 by cisco Systems, Inc.
System Bootstrap, Version 3.1(2)
Copyright (c) 1994-1997 by cisco Systems, Inc.
Presto processor with 32768 Kbytes of main memory
Autoboot executing command: "boot bootflash:cat6000-sup.5-4-1a.bin"
CCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCC
Uncompressing file: ###########################################################
System Power On Diagnostics
NVRAM Size .. .................512KB
ID Prom Test ..................Passed
DPRAM Size ....................16KB
DPRAM Data 0x55 Test ..........Passed
DPRAM Data 0xaa Test ..........Passed
DPRAM Address Test ............Passed
Clearing DPRAM ................Done
System DRAM Memory Size .......32MB
DRAM Data 0x55 Test ...........Passed
DRAM Data 0xaa Test ...........Passed
DRAM Address Test ............Passed
Clearing DRAM .................Done
EARLII ........................Present
EARLII RAM Test ...............Passed
EARL Serial Prom Test .........Passed
Level2 Cache ..................Present
Level2 Cache test..............Passed
Boot image: bootflash:cat6000-sup.5-4-1a.bin
Downloading epld sram device please wait ...
Programming successful for Altera 10K50 SRAM EPLD
This module is now in standby mode.
Console is disabled for standby supervisor
Task
Command
Reset the active supervisor engine (where
mod
is
the number of the active supervisor engine).
reset
mod