21-12
Catalyst 6500 Series Switch Software Configuration Guide—Release 8.7
OL-8978-04
Chapter 21 Configuring GOLD
Configuring Online Diagnostics
This example shows how to clear the bootup online diagnostic level:
Console> (enable)
clear diagnostic bootup level
Diagnostic level set to bypass
Console> (enable)
This example shows how to clear the online diagnostic event-log size:
Console> (enable)
clear diagnostic event-log size
Diagnostic event-log size set to default(500)
Console> (enable)
These examples show how to clear the online diagnostic monitoring configuration:
Console> (enable)
clear diagnostic monitor interval module 7 test 3
Clear diagnostic monitor interval for module 7 test 3
Console> (enable)
Console> (enable)
clear diagnostic monitor module 7 test 1
Module 7 test 1 diagnostic monitor disable.
Console> (enable)
Console> (enable)
clear diagnostic monitor syslog
Diagnostic monitor syslog disable.
Console> (enable)
Clear the online diagnostic scheduling configuration for tests 1 and 2 on module 7:
Console> (enable)
clear diagnostic schedule module 7 test 1-2 daily 12:12
Clear diagnostic schedule at daily 12:12 for module 7 test 1-2
Console> (enable)
Disable syslog generation that occurs when a test
fails.
clear diagnostic monitor syslog
Clear online diagnostic scheduling information.
clear diagnostic schedule module
mod_num
test
{
test-id
|
test-id-range
|
all
} {[
port
{
port_num
|
port_range
|
all
}] | [
device
{
device_num
|
device_range
|
all
}]}
Task