9-15
Catalyst 6500 Series Switch Software Configuration Guide—Release 8.7
OL-8978-04
Chapter 9 Configuring Spanning-Tree PortFast, UplinkFast, BackboneFast, and Loop Guard
Configuring UplinkFast on the Switch
Disabling PortFast BPDU Filtering
To disable PortFast BPDU filtering on the switch, perform this task in privileged mode:
This example shows how to disable PortFast BPDU filtering on the switch and verify the configuration:
Console> (enable)
set spantree portfast bpdu-filter disable
Spantree portfast bpdu-filter disabled on this switch.
Console> (enable)
show spantree summary
Summary of connected spanning tree ports by vlan
Portfast bpdu-filter disabled for bridge.
Uplinkfast disabled for bridge.
Backbonefast disabled for bridge.
Vlan Blocking Listening Learning Forwarding STP Active
----- -------- --------- -------- ---------- ----------
1 0 0 0 4 4
2 0 0 0 4 4
3 0 0 0 4 4
4 0 0 0 4 4
5 0 0 0 4 4
6 0 0 0 4 4
10 0 0 0 4 4
.
.
802 0 0 0 0 0
850 0 0 0 4 4
917 0 0 0 4 4
999 0 0 0 4 4
1003 0 0 0 0 0
1005 0 0 0 0 0
Blocking Listening Learning Forwarding STP Active
----- -------- --------- -------- ---------- ----------
Total 0 0 0 85 85
Console> (enable)
Configuring UplinkFast on the Switch
You can configure UplinkFast for PVST+ or for Multi-Instance Spanning Tree Protocol (MISTP). The
command is the same but the output may be slightly different.
Note
For additional MISTP information, see
Chapter 7, “Configuring Spanning Tree.”
These sections describe how to configure UplinkFast on the switch:
•
Enabling UplinkFast, page 9-16
•
Disabling UplinkFast, page 9-17
Task
Command
Step 1
Disable PortFast BPDU filtering on the switch.
set spantree portfast bpdu-filter disable
Step 2
Verify the PortFast BPDU filter setting.
show spantree summary
show portfast