20-77
Catalyst 6500 Series Switch Software Configuration Guide—Release 8.7
OL-8978-04
Chapter 20 Checking Status and Connectivity
Digital Optical Monitoring
Setting Transceiver Monitoring and Thresholds
The following sections describe how to set transceiver monitoring parameters and thresholds:
•
Enabling or Disabling Transceiver Monitoring, page 20-77
•
Setting the Transceiver Monitoring Interval, page 20-77
•
Setting the Transceiver Temperature Threshold, page 20-77
Enabling or Disabling Transceiver Monitoring
To enable or disable transceiver monitoring, perform this task in enabled mode:
This example shows how to enable transceiver monitoring:
Console> (enable)
set transceiver-monitoring enable
Transceiver monitoring is successfully enabled
This example shows how to disable transceiver monitoring:
Console> (enable)
set transceiver-monitoring disable
Transceiver monitoring is successfully disabled
Setting the Transceiver Monitoring Interval
To set the transceiver monitoring interval, perform this task in enabled mode:
This example shows how to set the transceiver monitoring interval:
Console> (enable)
set transceiver-monitoring interval 10
Transceiver monitoring interval is set to 10 minutes
Setting the Transceiver Temperature Threshold
To set a transceiver temperature threshold, perform this task in enabled mode:
This example shows how to set a transceiver temperature threshold without specifying the severity:
Task
Command
Enable transceiver monitoring.
set transceiver-monitoring [enable | disable]
Task
Command
Set the transceiver monitoring interval.
set transceiver-monitoring interval
minutes
Task
Command
Set a transceiver temperature threshold.
set port transceiver
mod/port
[
current | rx-power
| temperature | tx-power | voltage
] [
high-alarm |
high-warn | low-alarm | low-warn
]
severity
severity value