3
FI002K0018v1530hUK – THS/21 Instruction manual for installation, use and maintenance
INSTALLATION
86 ORIGINAL
INSTRUCTION
Small-size power supply
card
Connect the 24V power supply as indicated on picture,
to pins 2 and 3 of the J8 terminal.
3.5.6.1 Connection
to
earth
Connect an earthing wire to the
PE
terminal. The wire size must conform to current safety standards.
Wire cross-section: AWG14 or 2.5 mm
2
, maximum 6 mm
2
(AWG8).
The earth resistance must be lower than that required under the current rules of the country of
installation and, in any case, below 5 ohm.
Control Power Box
Conveyor Control System
3.5.6.2 Power Switch
On the
Conveyor Control System
model, the
On/Off switch
is located on the power supply unit
cover; in the case of the
Control Power Box
, an external switch must be fitted.
If necessary, the Conveyor Control System switch can be locked in the OFF
position with a padlock.
When the switch is in the OFF position, depress the central part of the switch
and insert the padlock in the slot created. In this way the switch cannot turn