3
FI002K0018v1530hUK – THS/21 Instruction manual for installation, use and maintenance
INSTALLAZIONE
114 ORIGINAL
INSTRUCTION
3.7.2 Settings of SW1 minidip
Connector Label
Default value
Description
SW1
M1/FR OFF
Reserved
M2 OFF
Reserved
M3 OFF
OFF: ejection activated (through EJECT NO/EJECT NC) in
case of Metal Detector power off.
ON: ejection NOT activated in case of power off.
The minidip ha no effect.
M4
OFF
+24V enabled on pin1 J10
3.7.3 00211AL_
card
Connector Pin Label
IN/OUT Type
Range/Max.
value
Function
J1
1
C
Output
common
30 V AC/DC 2.5A
Ready relay
2
NC N.C.
contact
3
NO N.O.
contact
4
C
Output
common
Ejector relay
5
NC N.C.
contact
6
NO N.O.
contact
J2
1
GND
Rese
rved
GND
Reserved for RCU connection
2
GND GND
3
TXD Data
4
RXD Data
5
+5V +5
V
6
+V
+24 V
J3
1
-
+24 V
100 mA max
RS-232 serial connection
The 24 V on pin 1 is present only if the minidip VRS232
of switcher SW1 is set to ON. By default it is set to
OFF.
2
RXD
3
TXD
5
0
V
6
DTR
J4
1
GND
-
GND
Auxiliary serial port communication
2
TXD Data
3
RXD Data
4
+V
+24 V
150 mA max
J5
1
GND
2
+Vin
Input
24V
Connection of ejection confirmation sensor
3 EJ.CONFIRM
4
0V 0V
5
+Vin
1
Input
24V
Connection of the synchronization photocell
6 Photocell
7
0V 0V
8
+Vin
1
Input
24V
Connection of a reset push-button
9 Reset
10
0V 0V
11
+Vin
1
Input
24V
Connection of an encoder
12 ENCODER
13
0V 0V
J6
Reserved