![Ceia THS/21 Скачать руководство пользователя страница 113](http://html1.mh-extra.com/html/ceia/ths-21/ths-21_instruction-manual-for-installation-use-and-maintenance_2579009113.webp)
FI002K0018v1530hUK – THS/21 Instruction manual for installation, use and maintenance
3
INSTALLAZIONE
ORIGINAL
INSTRUCTION 113
Connector Pin Label
IN/OUT Type
Range/Max.
value
Function
J17
1
GND
2
0V
0V
Connection of bin full level sensor
3 BIN
FULL
Input
4
+Vin
24V
2
5
0V
0V
Connection of an encoder
Maximum pulse frequency: 3 kHz
Type: push-pull 24 V
6 Encoder
Input
7
+Vin
24V
2
8
0V
0V
Connection of a low pressure sensor
9 Low
pressure
Input
10
+Vin
24V
2
11
0V
0V
Connection of a reset pushbutton (NO)
12 Reset
Input
13
+Vin
24V
2
14
0V
0V
Connection of the synchronization photocell
15 Photocell
Input
16
+Vin
24V
2
17
0V
0V
Connection of ejection confirmation sensor
18 EJ.CONFIRM
Input
19
+Vin
24V
2
J18
1
1
GND
GND
Connection of the beacon and horn
2
0V
0
V
3
RED LAMP
Output Fault signal
0/24V
4
YELLOW L.
Output Alarm signal 0/24V
5
BLUE LAMP
Output
Test req.
signal
0/24V
6
HORN Output
Sound
signal
0/24V
7
SPARE LAMP Output
Reset
backlight
0/24V
Backlighting of external button
connected to the
RESET input, activated by the Reset request
8
WHITE L.
Output Main signal
24V
J19
1
1
GND
GND
2
0V
0
V
3
EXT EM BUTTON
EXT EM
BUTTON
External emergency button (NC single contact)
If not used, keep jumpered
4
EXT EM BUTTON
5
EM STOP 1A
EM STOP 1
External emergency button connections (NC double
contact) 1 of 2. If not used, keep jumpered
6
EM STOP 1B
7
K1 NC
-
Reserved for connection to relay K1.
With Control Power Box, keep jumpered.
8
9
EM STOP 2A
EM STOP 2
External emergency button connections (NC double
contact) 2 of 2. If not used, keep jumpered
10
EM STOP 2B
11
-
Reserved for the connection with the contactor K1
12
-
13
-
1
Connector present only on
card, full version
2
The +Vin power supply can provide an
overall