![Ceia THS/21 Скачать руководство пользователя страница 155](http://html1.mh-extra.com/html/ceia/ths-21/ths-21_instruction-manual-for-installation-use-and-maintenance_2579009155.webp)
FI002K0018v1530hUK – THS/21 Instruction manual for installation, use and maintenance
4
USE OF THE DEVICE
ORIGINAL
INSTRUCTION 155
4.3.5 Signals given during self-diagnosis
The THS/21 Metal Detector has an embedded self-diagnosis system. The messages shown on the
display are given in section 5.5, with the simultaneous activation of the Alarm led on the front panel
and the indicators of the external optical/acoustical signalization lamp.
4.3.6 Other
signalizations
The Metal Detector shows on display some signalization related to its functioning status:
THS/xx21E
THS/xx21
THS/xx21E V5.xxx
Product: PROD01
^
CEIA THS/xx21
ALM V5.xxx THS V5.xxx
Product
:
PROD01
To show the Metal Detector activity, the
colons beside the selected product indication,
blinks.
THS/xx21E V5.xxx
Batch: 1234
^
CEIA THS/xx21
ALM V5.xxx THS V5.xxx
Batch
:
1234
If the system is set to include the batch
number also, on product selection, then the
batch number is shown alternatively to the
selected product name.
THS/xx21E V5.xxx
Product: PROD01
B
^
CEIA THS/xx21
ALM V5.xxx THS V5.xxx
B
Product
:
PROD01
If the system is correctly connected via BT
Wireless Communication, a symbol is shown
on the right side of the display. If the symbol
blinks, data transmission is in progress.