3
FI002K0018v1530hUK – THS/21 Instruction manual for installation, use and maintenance
INSTALLATION
76 ORIGINAL
INSTRUCTION
3.4.4 Pressure
adjustment
On CEIA Integrated Systems, the ejection system has a
factory preset at a suitable pressure for the installed ejector
type.
The pressure adjustment knob comes locked with a bolt and
a nut, replaceable by the Customer, with a padlock.
If necessary, it is possible to adjust it, up to a maximum of
0,6 MPa
.
1. Remove the lock (be it the factory bolt
or the padlock provided by the Customer)
2. Remove the cap
3. Open the protection and remove it from
the knob
4. Lift-up the knob
5. Rotate the knob clockwise, to increase,
or anti-clockwise, to decrease the
pressure
6. Press the knob down to lock it back
7. Place back the protection around the
knob
8. Place back the cap
9. Lock back