4
FI002K0018v1530hUK – THS/21 Instruction manual for installation, use and maintenance
USE OF THE DEVICE
166 ORIGINAL
INSTRUCTION
4.8.3 Performing an automatic test
This function is available only with ‘Ejection Mode’ set to ‘F’.
It is possible to perform some tests in automatic mode (see MTI parameter); during the automatic
test, the Metal Detector simulates the transit of the test sample by generating the same signal
produced at the last manual test, verifying the correct activation of the alarm and the ejector. If the
manual test has been triple (Test Fe, Test NFe, Test SS), it is performed by simulating the lowest
signal among those related to the passage of the three test samples.
The first test after switching on the Metal Detector, a change in the Detection, Ejection and Current
Product Speed parameters or a Fault condition, must be carried out manually by the operator using
standard procedure. Any subsequent automatic tests, defined according to the programming of MTI
parameter, will be performed automatically by the Metal Detector.
Automatic tests are performed only if the signal provided by the samples during the previous manual
test is at least 3dB. Otherwise, at the next scheduled test request, the Metal Detector will require a
new manual test.
Check that the Metal Detector is calibrated to detect test samples with a minimum amplitude of 3dB.
The automatic test is performed only during belt movement (if present); otherwise, the automatic test is automatically
delayed.
4.8.3.1 Automatic test sequence
THS/21E
THS/21
After the test interval, the message
‘TEST’
will be displayed for a few
second. If present, the external blue
lamp will start flashing quickly.
TEST
Product: PROD01
^
** TEST **
Product:PROD01
After a few seconds, the following
messages appear on the display::
=====================
WAIT
---------------------
[\\\\\\\\\\\\\\\\\\\]
WAIT
{|||||||||||||||||||}
Automatic test in progress.
=====================
AUTOMATIC TEST
---------------------
[\\\\\\\\\\\\\\\\\\\]
AUTOMATIC TEST
{|||||||||||||||||||}
Automatic test successfully
completed.
=====================
TEST PASSSED
Ej.Open.Time 0.323
Speed Check OK
TEST PASSED
Ej.Open.Time 0.323
Speed Check OK
Product:PROD01
At the end of the test, a message
appears on the display indicating
the next required test type.
=====================
TEST PASSED
Next test AUTOMATIC
---------------------
[\\\\\\\\\\\\\\\\\\\]
TEST PASSED
next test AUTOMATIC
{|||||||||||||||||||}
In every moment, through the Status screen under the heading
Next Test(x)
, it is possible to see the next
required test type (A: automatic, M: manual).