5
FI002K0018v1530hUK – THS/21 Instruction manual for installation, use and maintenance
MAINTENANCE
194 ORIGINAL
INSTRUCTION
Fault Message
Probable cause
Action
Type
BIN ABSENT/OPEN
Reject bin absent, with door
open or with the electric lock
released
Correctly place back the reject bin, close the door or
close again the electric lock
Check that the diagnosis activation delay (LAD) is
adequate for the application
Sensor connected to the BIN
ABSENT input faulty or
disconnected
Check the sensor mechanical and electrical
installation and its correct activation
In absence of the installed sensor, deactivate the
diagnosis (LA=OFF)
If the problem persists, contact Assistance Service.
BIN FULL
Rejected products bin full
Empty the rejected products bin
Check that the diagnosis activation delay (LFD) is
adequate for the application
Sensor connected to the BIN
FULL input faulty or
disconnected
Check the sensor mechanical and electrical
installation and its correct activation
In absence of the installed sensor, deactivate the
diagnosis (LF=OFF)
If the problem persists, contact Assistance Service
NO EJECT.CONFIRM
Ejection of the product in the bin
not occurred within the
programmed time limit (CT)
Check the correct electric and mechanical installation,
the correct pneumatic setup and activation of the
ejector.
Check that the time limit (CT) is adequate for the
application.
Complete activation of the
ejector not occurred within the
programmed time limit (CT)
Incorrect activation of the
Ejection Confirmation photocell
Check that the contaminated product (ejected inside
the bin) is correctly detected by the Ejection
Confirmation photocell
Multiple spurious readings on the
ejected package, by the
Synchronization photocell
or packages too close
Check that there have been packages not spaced
enough for their correct ejection
Check that the photocell is correctly set to aovid
spurious readings caused by the pack shape (see
PML and GML)
Incorrect parameters
Check that BS parameter or the speed read by the
encoder, correspond to the actual transit speed
Check that the ejector related parameters (ED, ERT)
are correctly set
Sensor connected to the
EJ.CONFIRMATION input faulty
or disconnected
Check the sensor mechanical and electrical
installation and its correct activation
In absence of the installed sensor, deactivate the
diagnosis (CE=OFF)
If the problem persists, contact Assistance Service