FI002K0018v1530hUK – THS/21 Instruction manual for installation, use and maintenance
3
INSTALLATION
ORIGINAL
INSTRUCTION
65
3.1.3.6 Selecting and installing connecting cables
The following instructions refer to connecting cables to external equipment and servo systems.
- Only use cables with a circular cross-section and a smooth surface.
- Only connect one cable to each cable gland.
- At the end of the installation, check that all cable glands are correctly tightened.
- In case of replacement, use CEIA cable glands and caps only. Refer to Spare Parts Manual.
Cable gland Only cable with an outer
diameter between:
M16
ø3.0 - ø10.0 mm
M20
ø5.0 - ø13.0 mm
M25
ø8.0 - ø17.0 mm
Close all non-used cable glands holes with the proper caps. Do not use the device with not-closed holes.
3.1.3.7 Multiple Metal Detectors close together
To prevent reciprocal interference between Metal Detectors which are positioned close to each other,
set different transmission channels for each detector. The minimum distance depends on the
Detection Probe dimensions and on the Metal Detector settings.
The command for assigning a different channel to a Metal Detector is
Configuration > TX Channel
.
To identify sources of electrical and mechanical noise which might disturb operation of the Metal Detector, see the
instructions in the Compatibility Procedure (section 5.5).