3
FI002K0018v1530hUK – THS/21 Instruction manual for installation, use and maintenance
INSTALLAZIONE
120 ORIGINAL
INSTRUCTION
3.9 Configuration
CEIA integrated systems are already configured (see Factory Acceptance Test enclosed with the
manual).
On non-integrated systems, the programming parameters must be set to match the type of
installation.
For instructions on entering the programming phase, refer to paragraph 4.5.
In the following section, access to Programming as Administrator is required.
User: ADMINI – Password: 000000
To keep things simple, the parameters will be referred to using the short name valid for remote programming.
3.9.1 System
start-up
If the equipment is being switched on for the first time, some checks must be carried out and the
value of some operating parameters must be set. These operations, which are listed on the first page
of the Installation section, are described below in this section.
Verify that the power supply door is properly closed before starting the System.
When it is first powered up, the Metal Detector configuration includes 6 factory-set passwords (shown on the test card at
the end of the manual).
It is extremely important that the person in charge of the detector modifies the passwords,
in order to avoid unauthorized access to programming
.
3.9.2 Preliminary
settings
- Enter
the
Configuration
menu and set the correct values for the following parameters:
Language
,
Date
and
Time
.
Check the correct settings for date and time in order to grant a correct traceability of all events recorded on the Metal
Detector memory. The DST setting, where it is applied, shall be performed manually.
- In the case of adjacent Metal Detectors, if necessary, set a transmission channel different from
the other Metal Detector, using the
TX channel
parameter.