FI002K0018v1530hUK – THS/21 Instruction manual for installation, use and maintenance
3
INSTALLATION
ORIGINAL
INSTRUCTION
59
Examples of roller insulation
Insulation of the roller pin
Insulation of the roller pin support
Insulation of the bearing support of a
roller pin
R
: roller;
B
: spacers in insulating material;
P
: side bulkhead of the belt frame
3.1.2.5 Synchronization
photocell
The Synchronization photocell enables a high degree of precision in ejecting contaminated material
and counting the product transiting through the unit.
Install the photocell as close as possible to the Metal Detector Detection Probe at the entrance or
the exit in the direction of transit depending on the ejection mode used (see paragraph 3.8.8).
The photocell must be connected to the PHOTOCELL input.
The photocell must be positioned at a height where the beam is always interrupted by the objects transiting on the
conveyor belt. It is also recommended to place it at the minimum possible distance from the Probe side and sufficiently
set back with respect to the transit tunnel, according to the free metal zone indicated on paragraph 3.1.2.2 (expecially
when it has a body or other elements made of metal).
F
S
N
PD
F
S
N
PD
Photocell installed at the entrance
Install the photocell as close as possible to the Detection
Probe entrance.
Photocell installed at the exit from the Probe
Install the photocell as close as possible to the Detection
Probe exit.
N
: conveyor belt;
S
: electronics unit;
F
: photocell;
PD
: distance photocell- electronics unit;
With Ejection Mode = FS (see section Configuration > Ejection mode) the photocell shall be installed at the Probe exit.
3.1.2.6 Metallic
flanges
Any metal flanges must be carefully insulated as shown in figure.
B
: materiale isolante;