Power up the device and perform the following procedure in an
interference-free environment, by deactivating any device around
the THS and other power devices in the area.
1.
Access to Programming on
Configuration-adv
menu
2.
Set the parameter
TA Autolearn
= ON
(TL=ON) and exit
Programming.
The message “TA Autolearn” will appear on the display:
press down firmly for at least a second on the Probe (as
shown alongside, do not press the centre line).
3.
Repeat the procedure for all Detection Modes (DM) or
Bands (BA) available and, for each one of them, for each
Transmission Channel (CH).
4.
At the end of the procedure, check the Metal Detector correct functioning for each of the
available Products; it may be necessary to perform a new Autolearn.
If there are environmental noises during the execution of TA Autolearn, it may be aborted (message “AUTOLEARN