FI002K0018v1530hUK – THS/21 Instruction manual for installation, use and maintenance
INSTALLAZIONE
112 ORIGINAL
INSTRUCTION
Connector Pin Label
IN/OUT Type
Range/Max.
value
Function
J15
1
0V
0V
Reserved
2
Right align.
photocell
Input
3
Right align.
valve
Output
0-24V
4
0V
0V
5
6
0V
0V
Reserved
7
Left align.
photocell
Input
8
Left align.
valve
Output
0-24V
9
0V
0V
10
11
0V
0V
12
13
14
15
0V
0V
Connection of Bin electric lock
16
Bin unlock
Output 24V
2
J16
1
1
0V
0V
Connection of ejection system check sensor
2 Ej.
check
Input
3
+Vin
24V
2
4
0V
0V
Connection of ejector position check sensor
5 EJ.POS.
CHK
Input
6
+Vin
24V
2
7
0V
0V
Connection of a button (NA) to activate Test
request
8 IN
AUX1
Input
9
+Vin
24V
2
10
0V
0V
Connection of bin absent sensor
11 Bin absent
Input
12
+Vin
24V
2
13
0V
0V
Connection of Metal Detector inhibition signal or to
force the ejection cycle
14 Inhibition
Input
15
+Vin
24V
2
16
0V
0V
Connection for Following Conveyor enabling signal
by means of a clean contact
17 Foll.Conv.
Input
18
+Vin
24V
2
1
Connector present only on
card, full version
2
The output can provide an
overall
maximum current of 150 mA. In case of an emergency, the output is set to 0 V.