142
Basic printing procedures
From the lowest position to the middle position
(1)
Detach the platen.
(2)
Remove the platen fixing lever, platen height adjustment lever.
The number of collars and the height adjustment range are as follows:
Position
Height
No. of collars
Highest position
(standard)
0 to 10 mm
2
Middle position
10 to 20 mm
1
Lowest position
20 to 30 mm
None
Case of 16×21 platen
Position
Height
No. of collars
Lowest position
0 to 10 mm
None
<TIPS>
Spacers are installed on your printer so that the height can be the reference value. Do not change the number of spacers.
X0266
(3)
Loosen the knob while holding the platen bearing and lift the platen bearing to the top to tighten the knob again.
X0267
Platen height adjustment lever
Platen fixing lever
Platen bearing
Knob
Spacer
Содержание GTX pro