47
[1.3 SETTINGS]
(SEt-)
(1) In corresponds to the rated drive current indicated in the Installation Manual or on the drive nameplate.
Code
Name/Description
Adjustment range
Factory setting
tA4
• [End Dec round]
10%
*
See page
123
- Rounding of end of deceleration ramp as a % of the
[Deceleration]
(dEC)
or
[Deceleration 2]
(dE2)
ramp time.
- Can be set between 0 and (100% –
[Begin Dec round]
(tA3)
)
LSP
• [Low speed]
0 Hz
Motor frequency at minimum reference, can be set between 0 and
[High speed]
(HSP)
.
HSP
• [High speed]
50 Hz
Motor frequency at maximum reference, can be set between
[Low speed]
(LSP)
and
[Max frequency]
(tFr)
.
The factory setting changes to 60 Hz if
[Standard mot. freq]
(bFr)
=
[60 Hz NEMA]
(60)
.
ItH
• [Mot. therm. current]
0 to 1.1 or 1.2 In (1)
according to rating
According to
drive rating
Motor thermal protection current, to be set to the rated current indicated on the nameplate.
SPG
• [Speed prop. gain]
0 to 1,000%
40%
Speed loop proportional gain
SIt
• [Speed time integral]
1 to 1,000%
100%
Speed loop integral time constant.
SFC
• [K speed loop filter]
0 to 100
0
Speed loop filter coefficient.
*
These parameters only appear if the corresponding function has been selected in another menu. When the parameters can
also be accessed and adjusted from within the configuration menu for the corresponding function, their description is detailed
in these menus, on the pages indicated, to aid programming.