145
[1.7 APPLICATION FUNCT.]
(FUn-)
(1) The parameter can also be accessed in the
[1.3 SETTINGS]
(SEt-)
menu.
(2) Range 0.01 to 99.99 s or 0.1 to 999.9 s or 1 to 9000 s according to
[Ramp increment]
(Inr)
page
122
.
Code
Name/Description
Adjustment range
Factory setting
•
[PID REGULATOR]
(continued)
FPI
• [Speed ref. assign.]
[No]
(nO)
nO
AI1
AI2
AI3
AI4
LCC
Mdb
CAn
nEt
APP
PI
PG
PID regulator predictive speed input
-
[No]
(nO)
: Not assigned (function inactive)
-
[AI1]
(AI1)
: Analog input
-
[AI2]
(AI2)
: Analog input
-
[AI3]
(AI3)
: Analog input, if VW3A3202 extension card has been inserted
-
[AI4]
(AI4)
: Analog input, if VW3A3202 extension card has been inserted
-
[HMI]
(LCC)
: Graphic display terminal
-
[Modbus]
(Mdb)
: Integrated Modbus
-
[CANopen]
(CAn)
: Integrated CANopen
-
[Com. card]
(nEt)
: Communication card (if inserted)
-
[Prog. card]
(APP)
: Controller Inside card (if inserted)
-
[RP]
(PI)
: Frequency input, if VW3A3202 extension card has been inserted
-
[Encoder]
(PG)
: Encoder input, if encoder card has been inserted
PSr
• [Speed input%]
(1)
1 to 100%
100%
Multiplying coefficient for predictive speed input.
The parameter cannot be accessed if
[Speed ref. assign.]
(FPI)
=
[No]
(nO)
.
PAU
• [Auto/Manual assign.]
[No]
(nO)
nO
LI1
-
-
-
-
[No]
(nO)
: The PID is always active.
-
[LI1]
(LI1)
:
:
-
[...]
(...)
: See the assignment conditions on page
109
.
If the assigned input or bit is at 0, the PID is active.
If the assigned input or bit is at 1, manual operation is active.
AC2
• [Acceleration 2]
(1)
0.01 to 9000 s (2)
5.0 s
Time to accelerate from 0 to the
[Rated motor freq.]
(FrS)
. Make sure that this value is compatible with the
inertia being driven.
Ramp AC2 is only active when the PID function is starting up and in the event of PID "wake-ups".
PIM
• [Manual reference]
[No]
(nO)
nO
AI1
AI2
AI3
AI4
PI
PG
Manual speed input. The parameter can be accessed if
[Auto/Manual assign.]
(PAU)
is not
[No]
(nO)
.
-
[No]
(nO)
: Not assigned (function inactive)
-
[AI1]
(AI1)
: Analog input
-
[AI2]
(AI2)
: Analog input
-
[AI3]
(AI3)
: Analog input, if VW3A3202 extension card has been inserted
-
[AI4]
(AI4)
: Analog input, if VW3A3202 extension card has been inserted
-
[RP]
(PI)
: Frequency input, if VW3A3202 extension card has been inserted
-
[Encoder]
(PG)
: Encoder input, if encoder card has been inserted
The preset speeds are active on the manual reference if they have been configured.
Parameter that can be modified during operation or when stopped.