203
[1.12 FACTORY SETTINGS]
(FCS-)
List of motor parameters
[1.4 MOTOR CONTROL] (drC-) menu:
[Rated motor power]
(nPr)
–
[Rated motor volt.]
(UnS)
–
[Rated mot. current]
(nCr) –
[Rated motor freq.]
(FrS) –
[Rated motor speed]
(nSP)
–
[Auto tuning]
(tUn) –
[Auto tuning status]
(tUS) –
[U/F Profile]
(PFL)
–
[U0]
(U0)
to
[U5]
(U5) –
[F1]
(F1)
to
[F5]
(F5) –
[V. constant power]
(UCP) -
[Freq. Const Power]
(FCP) –
[Nominal I sync.]
(nCrS) –
[Nom motor spdsync]
(nSPS) –
[Pole pairs]
(PPnS) –
[Syn. EMF constant]
(PHS) –
[Autotune L d-axis]
(LdS) –
[Autotune L q-axis]
(LqS) –
[Cust. stator R syn]
(rSAS) –
[IR compensation]
(UFr) –
[Slip compensation]
(SLP) –
motor parameters that can be accessed in
[Expert]
mode, page
69
.
[1.3 SETTINGS] (SEt-) menu:
[Mot. therm. current]
(ItH)
Example of total return to factory settings
1.
1.
1.
1.
[Config. Source]
(FCSI)
=
[Macro-Conf]
(InI)
2.
2.
2.
2.
[PARAMETER GROUP LIST]
(FrY-)
=
[All]
(ALL)
3.
3.
3.
3.
[Goto FACTORY SETTINGS]
(GFS
=
YES)
Code
Name/Description
FCSI
• [Config. Source]
InI
CFG1
CFG2
Choice of source configuration. The parameter cannot be accessed if the drive has locked on an
[Incorrect config.]
(CFF) fault.
-
[Macro-Conf]
(InI)
Factory configuration, return to selected macro configuration.
-
[Config 1]
(CFG1)
-
[Config 2]
(CFG2)
If the configuration switching function is configured, it will not be possible to access
[Config 1]
(CFG1)
and
[Config 2]
(CFG2)
.
FrY-
• [PARAMETER GROUP LIST]
ALL
drM
SEt
MOt
COM
PLC
MOn
dIS
Selection of menus to be loaded
-
[All]
(ALL)
: All parameters.
-
[Drive menu]
(drM)
: The [1 DRIVE MENU] menu without [1.9 COMMUNICATION] and [1.14
PROGRAMMABLE CARD]. In the [7 DISPLAY CONFIG.]
menu,
[Return std name]
page
215
returns to
[No]
.
-
[Settings]
(SEt)
: The [1.3 SETTINGS] menu without the
[IR compensation]
(UFr)
,
[Slip compensation]
(SLP)
and
[Mot. therm. current]
(ItH)
parameters.
-
[Motor param]
(MOt)
: Motor parameters, see list below.
The following selections can only be accessed if
[Config. Source]
(FCSI)
=
[Macro-Conf.]
(InI)
:
-
[Comm. menu]
(COM)
: The [1.9 COMMUNICATION] menu without either
[Scan. IN1 address]
(nMA1)
to
[Scan. IN8 address]
(nMA8)
or
[Scan.Out1 address]
(nCA1)
to
[Scan.Out8 address]
(nCA8)
.
-
[Prog. card menu]
(PLC)
: the [1.14 PROGRAMMABLE CARD] menu.
-
[Monitor config.]
(MOn)
: The [6 MONITORING CONFIG.] menu.
-
[Display config.]
(dIS)
: the [7 DISPLAY CONFIG.] menu.
See the multiple selection procedure on page
23
for the integrated display terminal and page
13
for the graphic
display terminal.
Note: In factory configuration and after a return to “factory settings”, [PARAMETER GROUP LIST] will
be empty.
GFS
• [Goto FACTORY SETTINGS]
nO
YES
It is only possible to revert to the factory settings if at least one group of parameters has previously been
selected.
With the integrated display terminal:
- No
- Yes: The parameter changes back to nO automatically as soon as the operation is complete.
With the graphic display terminal: See the previous page.
SCSI
• [Save config]
nO
Str0
Str1
Str2
-
[No]
(nO)
:
-
[Config 0]
(Str0)
: Press the “ENT” key for 2 s.
-
[Config 1]
(Str1)
: Press the “ENT” key for 2 s.
-
[Config 2]
(Str2)
: Press the “ENT” key for 2 s.
The active configuration to be saved does not appear for selection. For example, if the active configuration is
[Config 0]
(Str0)
, only
[Config 1]
(Str1)
and
[Config 2]
(Str2)
appear. The parameter changes back to
[No]
(nO)
automatically as soon as the operation is complete.