![BLEMO ER40-G Скачать руководство пользователя страница 136](http://html.mh-extra.com/html/blemo/er40-g/er40-g_programming-manual_2772420136.webp)
136
[1.7 APPLICATION FUNCT.]
(FUn-)
(1) The parameter can also be accessed in the
[1.3 SETTINGS]
(SEt-)
menu.
(2) Range 0.01 to 99.99 s or 0.1 to 999.9 s or 1 to 9,000 s according to
[Ramp increment]
(Inr)
page
122
.
Code
Name/Description
Adjustment range
Factory setting
SrE
-
•
[+/-SPEED AROUND REF.]
The function can be accessed for reference channel
[Ref.1 channel]
(Fr1)
.
Note: This function cannot be used with certain other functions. Follow the instructions on page
115
.
USI
• [+ speed assignment]
[No]
(nO)
nO
LI1
-
-
-
-
[No]
(nO)
: Function inactive
-
[LI1]
(LI1)
:
:
-
[...]
(...)
: See the assignment conditions on page
109
.
Function active if the assigned input or bit is at 1.
dSI
• [-Speed assignment]
[No]
(nO)
nO
LI1
-
-
-
-
[No]
(nO)
: Function inactive
-
[LI1]
(LI1)
:
:
-
[...]
(...)
: See the assignment conditions on page
109
.
Function active if the assigned input or bit is at 1.
SrP
• [+/-Speed limitation]
0 to 50%
10%
This parameter limits the variation range with +/- speed as a % of the reference. The ramps used in this
function are
[Acceleration 2]
(AC2)
and
[Deceleration 2]
(dE2)
.
The parameter can be accessed if +/- speed is assigned.
AC2
• [Acceleration 2]
(1)
0.01 to 9,000 s (2)
5.0 s
Time to accelerate from 0 to the
[Rated motor freq.]
(FrS)
. Make sure that this value is compatible with the
inertia being driven.
The parameter can be accessed if +/- speed is assigned.
dE2
• [Deceleration 2]
(1)
0.01 to 9,000 s (2)
5.0 s
Time to decelerate from the
[Rated motor freq.]
(FrS)
to 0. Make sure that this value is compatible with the
inertia being driven. The parameter can be accessed if +/- speed is assigned.
Parameter that can be modified during operation or when stopped.