![BLEMO ER40-G Скачать руководство пользователя страница 168](http://html.mh-extra.com/html/blemo/er40-g/er40-g_programming-manual_2772420168.webp)
168
[1.7 APPLICATION FUNCT.]
(FUn-)
(1) The parameter can also be accessed in the
[1.3 SETTINGS]
(SEt-)
menu.
Code
Name/Description
Adjustment range
Factory setting
nFS-
•
[NO FLOW DETECTION]
nFS
• [No Flow Sensor]
[No]
(nO)
nO
LI1
-
-
C101
-
-
-
Cd00
-
Assignment of the zero fluid sensor.
-
[No]
(nO)
: Function inactive
-
[LI1]
(LI1)
to
[LI6]
(LI6)
-
[LI7]
(LI7)
to
[LI10]
(LI10)
: If VW3A3201 logic I/O card has been inserted
-
[LI11]
(LI11)
to
[LI14]
(LI14)
: If VW3A3202 extended I/O card has been inserted
-
[C101]
(C101)
to
[C115]
(C115)
: With integrated Modbus in [I/O profile] (IO)
-
[C201]
(C201)
to
[C215]
(C215)
: With integrated CANopen in [I/O profile] (IO)
-
[C301]
(C301)
to
[C315]
(C315)
: With a communication card in [I/O profile] (IO)
-
[C401]
(C401)
to
[C415]
(C415)
: With a Controller Inside card in [I/O profile] (IO)
-
[CD00]
(Cd00)
to
[CD13]
(Cd13)
: In [I/O profile] (IO) can be switched with possible logic inputs
-
[CD14]
(Cd14)
to
[CD15]
(Cd15)
: In [I/O profile] (IO) can be switched without logic inputs
If the assigned input is at 0, this indicates that there is no fluid present.
nFFt
• [Freq.Th.Sensor. Act.]
(1)
0 to 500 or 1,000 Hz
according to rating
0 Hz
Zero fluid detection activation threshold
The parameter can be accessed if
[No Flow Sensor]
(nFS)
is not
[No]
(nO)
.
nFSt
• [Flow Times Ctrl]
(1)
0 to 999 s
10 s
Zero fluid detection activation time delay
The parameter can be accessed if
[No Flow Sensor]
(nFS)
is not
[No]
(nO)
.
Parameter that can be modified during operation or when stopped.