[1.5 INPUTS / OUTPUTS CFG]
(I-O-)
Configuration of the encoder input serving as a reference, with a frequency
generator
This reference is not signed, therefore the directions of operation must be given via the control channel (logic inputs, for example).
Minimum and maximum values (input values):
The minimum value corresponds to a minimum reference of 0% and the maximum value to a maximum reference of 100%. The minimum
value may be greater than the maximum value. It may also be negative.
A reference can be obtained at zero frequency by assigning a negative value to the minimum value.
Reference
100%
0
[Freq. min.
value]
(EIL)
[Freq. max.
value]
(EFr)
300 kHz
Reference
100%
0
[Freq. min.
value]
(EIL)
[Freq. max.
value]
(EFr)
Frequency
input
Frequency
input
300 kHz
Reference
100%
[Freq. min.
value]
(EIL)
[Freq. max.
value]
(EFr)
300 kHz
Frequency
input
0