[1.7 APPLICATION FUNCT.]
(FUn-)
Code
Name/Description
Adjustment range
Factory setting
UPd-
•
[+/-Speed]
Function can be accessed if reference channel
[Ref.2 channel]
(Fr2)
=
[+/-Speed]
(UPdt)
see page
111
.
Note: This function cannot be used with certain other functions. Follow the instructions on page
115
.
USP
• [+ speed assignment]
[No]
(nO)
nO
LI1
-
-
C101
-
-
-
Cd00
-
-
[No]
(nO)
: Function inactive
-
[LI1]
(LI1)
to
[LI6]
(LI6)
-
[LI7]
(LI7)
to
[LI10]
(LI10)
: If VW3A3201 logic I/O card has been inserted
-
[LI11]
(LI11)
to
[LI14]
(LI14)
: If VW3A3202 extended I/O card has been inserted
-
[C101]
(C101)
to
[C115]
(C115)
: With integrated Modbus in [I/O profile] (IO)
-
[C201]
(C201)
to
[C215]
(C215)
: With integrated CANopen in [I/O profile] (IO)
-
[C301]
(C301)
to
[C315]
(C315)
: With a communication card in [I/O profile] (IO)
-
[C401]
(C401)
to
[C415]
(C415)
: With a Controller Inside card in [I/O profile] (IO)
-
[CD00]
(Cd00)
to
[CD13]
(Cd13)
: In [I/O profile] (IO) can be switched with possible logic inputs
-
[CD14]
(Cd14)
to
[CD15]
(Cd15)
: In [I/O profile] (IO) can be switched without logic inputs
Function active if the assigned input or bit is at 1.
dSP
• [-Speed assignment]
[No]
(nO)
nO
LI1
-
-
C101
-
-
-
Cd00
-
-
[No]
(nO)
: Function inactive
-
[LI1]
(LI1)
to
[LI6]
(LI6)
-
[LI7]
(LI7)
to
[LI10]
(LI10)
: If VW3A3201 logic I/O card has been inserted
-
[LI11]
(LI11)
to
[LI14]
(LI14)
: If VW3A3202 extended I/O card has been inserted
-
[C101]
(C101)
to
[C115]
(C115)
: With integrated Modbus in [I/O profile] (IO)
-
[C201]
(C201)
to
[C215]
(C215)
: With integrated CANopen in [I/O profile] (IO)
-
[C301]
(C301)
to
[C315]
(C315)
: With a communication card in [I/O profile] (IO)
-
[C401]
(C401)
to
[C415]
(C415)
: With a Controller Inside card in [I/O profile] (IO)
-
[CD00]
(Cd00)
to
[CD13]
(Cd13)
: In [I/O profile] (IO) can be switched with possible logic inputs
-
[CD14]
(Cd14)
to
[CD15]
(Cd15)
: In [I/O profile] (IO) can be switched without logic inputs
Function active if the assigned input or bit is at 1.
Str
• [Reference saved]
[No]
(nO)
nO
rAM
EEP
Associated with the “+/- speed” function, this parameter can be used to save the reference:
• When the run commands disappear (saved to RAM)
• When the line supply or the run commands disappear (saved to EEPROM)
Therefore, the next time the drive starts up, the speed reference is the last reference saved.
-
[No]
(nO)
: No save (the next time the drive starts up, the speed reference is
[Low speed]
(LSP)
,
see page
35
)
-
[RAM]
(rAM)
: Save to RAM
-
[EEprom]
(EEP)
: Save to EEPROM