Action and Event Tables
96
Field
Function
Alarm
Enter the alarm issued by the protected device or an ASG
Guard/ASG Guard Plus internal event (internal events are listed at
the end of this chapter) and press the ENTER key.
Action Routine
Enter the name of the Action Routine. The Action Routines included
with each ASG Guard/ASG Guard Plus are listed below. Press the
SPACE BAR until the desired choice is displayed. In addition,
custom Action Routines may be written. A detailed description of
each standard Action Routine is included in Chapter 14.
CANCEL = Cancels a pending Action Routine.
CLKAHEAD = Advances the ASG Guard/ASG Guard Plus clock by
one hour.
CLKBACK = Sets back the ASG Guard/ASG Guard Plus clock by
one hour.
CLKCHECK = Checks if current date is equal to first Sunday in
April or last Sunday in October. If so, schedules either a
CLKAHEAD (April) or CLKBACK (October) to occur at 2:00 AM.
DOLIST = Causes a list of Action Routines to be performed.
LOG = Creates a log entry describing the event.
LOGCHECK = Checks if the log buffer has reached a specified
threshold. If log has exceeded threshold, a .LOGFULL event is
generated
NOACTION = No action is taken.
PAGE = Calls a numeric pager and delivers a message.
PHIRIS = Places a call to IRIS
SM
and reports the event.
PHONHOME = Places a call to the maintenance reporting center.
PHPPP = Initiates a demand-dial PPP link.
PHSYSOP = Places a call to the maintenance center and initiates a
Sysop session with Admin Catcher.
REMINIT = Performs the remote initialization function.
RESRELAY = Sets the specified relay(s) to the normally closed
(N/C) state.
SCHEDULE = Schedules an Action Routine to occur at a defined
time
SETHP = Changes the setting of the Host Processing Flag
SETRELAY = Sets the specified relay(s) to the normally open
(N/O) state (applies only to ASG Guard/ASG Guard Plus units with
expansion board)
SNMPTRAP = Sends an SNMP trap to remote managers through
the Ethernet or PPP link.
Routine Parameters
Enter parameters associated with the Action Routine. Enter values
for parameters associated with the specified Action Routine.
Parameters must be separated by commas. A comma is not
needed at the end of the field. If you want to skip a parameter,
place a comma for the parameter and a second one to separate it
from the next parameter. For example, to enter the first and third
parameters (skip the second parameter), enter two commas in the
middle: 1,,3.
Comments
Type any comments you want attached to the event. Then press
the ENTER key.
Содержание Lucent Technologies Access Security Gateway Guard
Страница 12: ...x Page intentionally left blank ...
Страница 28: ...ASG Guard Overview 16 Page intentionally left blank ...
Страница 36: ...Physical Connections 24 Page intentionally left blank ...
Страница 60: ...Modem Port Setup 48 Page intentionally left blank ...
Страница 82: ...Modifying the User Database 70 Page intentionally left blank ...
Страница 106: ...Action and Event Tables 94 ACTION TABLE WORKSHEET Alarm Message or Internal Event Action Routine Routine Parameters ...
Страница 120: ...Action and Event Tables 108 Page intentionally left blank ...
Страница 158: ...User Connectivity 146 Page intentionally left blank ...
Страница 188: ...Log Functions 176 Page intentionally left blank ...
Страница 236: ...Troubleshooting 224 Page intentionally left blank ...
Страница 252: ...Internal Battery Replacement 240 Page intentionally left blank ...
Страница 258: ...Glossary of Command References 246 Page intentionally left blank ...