Events and Action Routines
197
Alarm/Event
Action Routine
Parameters
Comments
DTI030
PHSYSOP
3,1
This example phones the Sysop at Phone Home Number 3 and places the terminal in a Level 1
Sysop session when the DTI030 external event occurs.
14.4.14 REMINIT Action Routine
The REMINIT Action Routine performs the Remote Initialization function. REMINIT is usually
performed as the result of the Schedule Action Item (SAI) command or a SIT inserted into the
TAG port at power up. Prior to phoning home for initialization, the Comment field, up to @, is put
into the Site ID, and the Comment field, after @), is put into the Unit Phone number field in the
system parameters. If the Site ID and Phone number are not to be updated, then the comment
field must be left blank.
REMINIT also schedules a repeat execution five minutes after the first to ensure that a retry is
performed if the initialization transfer is aborted before completion.
Format: REMINIT
Resource Required:
Modem
Parameters:
phone number
1 to 3 - For home phone number 1, 2, or 3 (from system parameters)
or
Phone Number - Phone number to call. If omitted, Home Phone
Number 1 is used.
Example:
Alarm/Event
Action Routine
Parameters
Comments
POWEUP
REMINIT
5551212,4
.SITE442@6667854
This example performs a remote initialization of the ASG Guard/ASG Guard Plus located by
using phone number 555-1212. The ASG Guard/ASG Guard Plus calls in as a master level
access class. Included in the header of the call are a site ID (SITE442) and a site phone number
(6667854).
Содержание Lucent Technologies Access Security Gateway Guard
Страница 12: ...x Page intentionally left blank ...
Страница 28: ...ASG Guard Overview 16 Page intentionally left blank ...
Страница 36: ...Physical Connections 24 Page intentionally left blank ...
Страница 60: ...Modem Port Setup 48 Page intentionally left blank ...
Страница 82: ...Modifying the User Database 70 Page intentionally left blank ...
Страница 106: ...Action and Event Tables 94 ACTION TABLE WORKSHEET Alarm Message or Internal Event Action Routine Routine Parameters ...
Страница 120: ...Action and Event Tables 108 Page intentionally left blank ...
Страница 158: ...User Connectivity 146 Page intentionally left blank ...
Страница 188: ...Log Functions 176 Page intentionally left blank ...
Страница 236: ...Troubleshooting 224 Page intentionally left blank ...
Страница 252: ...Internal Battery Replacement 240 Page intentionally left blank ...
Страница 258: ...Glossary of Command References 246 Page intentionally left blank ...