Action and Event Tables
104
8.8 Internal Alarms and Events
In addition to the alarms generated by the Host or PBX system, the ASG Guard/ASG Guard Plus
supports several internal events. Chapter 14 contains a complete description of each internal
event and standard Action Routines and required parameters.
Table 8-1. Internal Events
Event
Description
.AUTHFAIL
Event occurs upon receipt of a failed authentication attempt.
.BAT48HIGH
Event occurs when battery voltage crosses over from an OK condition to a
high voltage condition. Use the SSA command to specify the upper limit.
.BAT48LOW
Event occurs when battery voltage crosses over from an OK condition to a low
voltage condition. Use the SSA command to specify the upper and lower
limits.
.BAT48OK
Event occurs when battery changes from a high or low condition to an OK
condition. Use the SSA command to specify the upper and lower limits.
.BUFREADY
Event occurs when a buffer file has been closed and is ready to be sent.
.C#CLOSED
Event indicating that the contact closure input has been changed from open to
closed, for example, .C3CLOSED.
.C#OPEN
Event indicating that the contact closure input has been changed from closed
to open, for example, .C3OPEN.
.CLKCHANGE
Event indicating that the internal clock of the ASG Guard/ASG Guard Plus has
changed.
.DISKCRIT
Event occurs when the RAMdrive reaches the critical level assigned by the Set
Disk Parameters command.
.DISKFULL
Event occurs when the RAMdrive is full. All further attempts to write to the disk
will be unsuccessful.
.DTRHIGH.n
Event occurs when the host or PBX asserts DTR (or host cable is connected),
e.g DTRHIGH1( indicates the host or PBX on host port number 1 has
asserted DTR or the host cable is connected (# indicates host port number).
.DTRLOW.n
Event occurs when the host or PBX stops asserting DTR or the physical
connection is lost between ASG Guard/ASG Guard Plus and the host or PBX
(# indicates the host port number).
.HOURLY
Event occurs at the top of each hour.
.INTBATLOW
Event occurs when the internal battery status has been changed from OK to
Low. A “low” battery status indicates that the voltage is less than 11 volts.
Содержание Lucent Technologies Access Security Gateway Guard
Страница 12: ...x Page intentionally left blank ...
Страница 28: ...ASG Guard Overview 16 Page intentionally left blank ...
Страница 36: ...Physical Connections 24 Page intentionally left blank ...
Страница 60: ...Modem Port Setup 48 Page intentionally left blank ...
Страница 82: ...Modifying the User Database 70 Page intentionally left blank ...
Страница 106: ...Action and Event Tables 94 ACTION TABLE WORKSHEET Alarm Message or Internal Event Action Routine Routine Parameters ...
Страница 120: ...Action and Event Tables 108 Page intentionally left blank ...
Страница 158: ...User Connectivity 146 Page intentionally left blank ...
Страница 188: ...Log Functions 176 Page intentionally left blank ...
Страница 236: ...Troubleshooting 224 Page intentionally left blank ...
Страница 252: ...Internal Battery Replacement 240 Page intentionally left blank ...
Страница 258: ...Glossary of Command References 246 Page intentionally left blank ...