Events and Action Routines
182
This example schedules a PHONHOME to report the alarm two minutes after DTR is lost
(transitions from high to low). If DTR is re-established (DTR goes high), the .DTRHIGH alarm
occurs and cancels the action PHONHOME Action Routine. Since no port number is specified,
this event will occur when DTR is lost on any port.
Alarm/Event
Action Routine
Parameters
Comments
.DTRLOW.1
PHONHOME
This example initiates a PHONHOME if the Data Terminal Ready (DTR) signal is lost only on host
port 1.
14.3.14 .HOURLY Internal Event
This event occurs automatically at the beginning of each hour (that is, 1:00, 2:00, 3:00, etc.).
Actions assigned to this event are performed every hour on the hour.
Alarm/Event
Action Routine
Parameters
Comments
.HOURLY
LOGCHECK
This example checks if the log buffer is approaching its limit. If that is the case, the internal event
.LOGFULL is generated.
14.3.15 .INTBATLOW Internal Event
The status of the internal battery has changed from OK to low.
Alarm/Event
Action Routine
Parameters
Comments
.INTBATLOW
PHONHOME
In this example, the PHONHOME Action Routine is initiated when the internal battery is low. After
the alarm is received, a technician may be sent to the site.
14.3.16 .INTBATOK Internal Event
The .INTBATOK alarm is generated when the status of the internal battery changes from low to
OK. This indicates that the internal battery has been recharged or replaced.
Alarm/Event
Action Routine
Parameters
Comments
.INTBATOK
CANCEL
.INTBATLOW
In the above example, the status of the internal battery has changed from low to OK, resulting in
the canceling of the phone call to the maintenance center for the battery low alarm.
Содержание Lucent Technologies Access Security Gateway Guard
Страница 12: ...x Page intentionally left blank ...
Страница 28: ...ASG Guard Overview 16 Page intentionally left blank ...
Страница 36: ...Physical Connections 24 Page intentionally left blank ...
Страница 60: ...Modem Port Setup 48 Page intentionally left blank ...
Страница 82: ...Modifying the User Database 70 Page intentionally left blank ...
Страница 106: ...Action and Event Tables 94 ACTION TABLE WORKSHEET Alarm Message or Internal Event Action Routine Routine Parameters ...
Страница 120: ...Action and Event Tables 108 Page intentionally left blank ...
Страница 158: ...User Connectivity 146 Page intentionally left blank ...
Страница 188: ...Log Functions 176 Page intentionally left blank ...
Страница 236: ...Troubleshooting 224 Page intentionally left blank ...
Страница 252: ...Internal Battery Replacement 240 Page intentionally left blank ...
Страница 258: ...Glossary of Command References 246 Page intentionally left blank ...