Modifying the User Database
57
6.5.2 Password/Callback Authentication Method
If Password/Callback was selected as the primary authentication method, the ASG Guard/ASG
Guard Plus will display the following information. .
•
Password/Callback Details—
Enter Password **********
Verify Password **********
Access Option Regular Callback
Screen 6-7. Password/Callback Details Screen
Field
Function
Enter a password
The password may be up to 15 alphanumeric characters.
Asterisks appear on the screen as you type to prevent
your password being displayed on the screen. Press the
ENTER key.
NOTE: Passwords are case sensitive.
Verify password
Retype the password exactly as you entered it the first
time, and then press the ENTER key.
Access Options
Press the SPACE BAR until the desired choice is
displayed for the Access Options. Three options are
available: Regular Callback, Passthru and Variable
Callback. Each option is discussed in subsequent
paragraphs.
When the access option you desire appears on the screen, press the ENTER key to make your
selection.
6.5.2.1 Access Option: Regular Callback
Regular Callback requires the user to have a specific phone number listed in the ASG
Guard/ASG Guard Plus user database, in addition to the password. After receiving a phone call
followed by the corresponding user name and password, the ASG Guard/ASG Guard Plus
disconnects the call and the caller hangs up. ASG Guard/ASG Guard Plus then dials the caller
back using the number in its database for that user and requests the password. After the
password is entered correctly, the user is allowed access.
If Regular Callback is selected, you are prompted to enter a phone number.
•
Password/Callback Details
Enter Password **********
Verify Password **********
Access Option Regular Callback
Phone Number 19085553435
Screen 6-8. Password/Callback Details Screen
Содержание Lucent Technologies Access Security Gateway Guard
Страница 12: ...x Page intentionally left blank ...
Страница 28: ...ASG Guard Overview 16 Page intentionally left blank ...
Страница 36: ...Physical Connections 24 Page intentionally left blank ...
Страница 60: ...Modem Port Setup 48 Page intentionally left blank ...
Страница 82: ...Modifying the User Database 70 Page intentionally left blank ...
Страница 106: ...Action and Event Tables 94 ACTION TABLE WORKSHEET Alarm Message or Internal Event Action Routine Routine Parameters ...
Страница 120: ...Action and Event Tables 108 Page intentionally left blank ...
Страница 158: ...User Connectivity 146 Page intentionally left blank ...
Страница 188: ...Log Functions 176 Page intentionally left blank ...
Страница 236: ...Troubleshooting 224 Page intentionally left blank ...
Страница 252: ...Internal Battery Replacement 240 Page intentionally left blank ...
Страница 258: ...Glossary of Command References 246 Page intentionally left blank ...