Events and Action Routines
183
14.3.17 .LOGFULL Internal Event
This event is a result of the LOGCHECK Action Routine when it detects that the LOG has passed
a specified capacity threshold. In order for the .LOGFULL event to occur, the LOGCHECK
routine must be associated with some regularly occurring event (such as .DAILY or .HOURLY).
Example:
Alarm/Event
Action Routine
Parameters
Comments
.LOGFULL
PHSYSOP
555-4321,3
This example initiates a call to 555-4321 and then establishes an access class 3 Sysop session.
The computer at 555-4321 could be programmed to receive the Site ID, extract the LOG from the
ASG Guard/ASG Guard Plus, and then issue the Clear Log History (CLH) command (see Section
13.3).
14.3.18 .MAXRETRY Internal Event
This event is generated by PHONHOME, PHIRIS, PHSYSOP, or PAGE. It will occur after the
value entered for the Max. Retries system parameter is surpassed.
Example:
Alarm/Event
Action Routine
Parameters
Comments
.MAXRETRY
PHONHOME
2
This example initiates a PHONHOME to Home Phone Number 2, as defined in the System
Parameter table, when the maximum retry counter has been exceeded.
14.3.19 .MDMINITERR Internal Event
This alarm is generated when a modem initialization error occurs.
Alarm/Event
Action Routine
Parameters
Comments
.MDMINITERR
SNMPTRAP
1
Modem error
14.3.20 .MEMLOW Internal Event
The alarm .MEMLOW is generated on the hour if fewer than 4KB (4096 bytes) are available on
the ASG Guard/ASG Guard Plus variable area.
Example:
Alarm/Event
Action Routine
Parameters
Comments
.MEMLOW
PHONHOME
Memory low
Содержание Lucent Technologies Access Security Gateway Guard
Страница 12: ...x Page intentionally left blank ...
Страница 28: ...ASG Guard Overview 16 Page intentionally left blank ...
Страница 36: ...Physical Connections 24 Page intentionally left blank ...
Страница 60: ...Modem Port Setup 48 Page intentionally left blank ...
Страница 82: ...Modifying the User Database 70 Page intentionally left blank ...
Страница 106: ...Action and Event Tables 94 ACTION TABLE WORKSHEET Alarm Message or Internal Event Action Routine Routine Parameters ...
Страница 120: ...Action and Event Tables 108 Page intentionally left blank ...
Страница 158: ...User Connectivity 146 Page intentionally left blank ...
Страница 188: ...Log Functions 176 Page intentionally left blank ...
Страница 236: ...Troubleshooting 224 Page intentionally left blank ...
Страница 252: ...Internal Battery Replacement 240 Page intentionally left blank ...
Страница 258: ...Glossary of Command References 246 Page intentionally left blank ...