14.3.29 .TEMPHIGH
The .TEMPHIGH event occurs when the temperature being monitored crosses over from an OK
threshold to a high temperature threshold. These thresholds are set by using the Set Sensor
Alarms (SSA) command (see Section 10.7).
Example:
Alarm/Event
Action Routine
Parameters
Comments
TEMPHIGH
DOLIST
.TEMPHIGH-1
PHONHOME
.TEMPHIGH-2
SCHEDULE
10 PHONHOME
This example activates a call to the maintenance reporting center when the .TEMPHIGH
condition occurs. Unless the alarm is canceled, the maintenance center is called again in 10
minutes.
14.3.30 .TEMPLOW Internal Events
The .TEMPLOW event occurs when the temperature being monitored crosses over from an OK
threshold to a low temperature threshold. These thresholds are set using the Set Sensor Alarms
(SSA) command (see Section 10.7).
Example:
Alarm/Event
Action Routine
Parameters
Comments
.TEMPLOW
PHONHOME
This example activates a call to the maintenance reporting center when the .TEMPLOW condition
occurs.
14.3.31 .TEMPOK Internal Events
The .TEMPOK event occurs when the temperature being monitored crosses over from a low
temperature or high temperature threshold to an OK threshold. These thresholds are set using
the Set Sensor Alarms (SSA) command (see Section 10.7).
Example:
Alarm/Event
Action Routine
Parameters
Comments
.TEMPOK
DOLIST
.TEMPOK-1
CANCEL
.TEMPHIGH
.TEMPOK-2
CANCEL
.TEMPLOW
Содержание Lucent Technologies Access Security Gateway Guard
Страница 12: ...x Page intentionally left blank ...
Страница 28: ...ASG Guard Overview 16 Page intentionally left blank ...
Страница 36: ...Physical Connections 24 Page intentionally left blank ...
Страница 60: ...Modem Port Setup 48 Page intentionally left blank ...
Страница 82: ...Modifying the User Database 70 Page intentionally left blank ...
Страница 106: ...Action and Event Tables 94 ACTION TABLE WORKSHEET Alarm Message or Internal Event Action Routine Routine Parameters ...
Страница 120: ...Action and Event Tables 108 Page intentionally left blank ...
Страница 158: ...User Connectivity 146 Page intentionally left blank ...
Страница 188: ...Log Functions 176 Page intentionally left blank ...
Страница 236: ...Troubleshooting 224 Page intentionally left blank ...
Страница 252: ...Internal Battery Replacement 240 Page intentionally left blank ...
Страница 258: ...Glossary of Command References 246 Page intentionally left blank ...