Configuration Files
220
C.7.3 CDUMPF Procedure
C.7.3.1 Overview
The CDUMPF command allows the user to copy the Customer User Table to the RAM disk of an
ASG Guard/ASG Guard Plus.
C.7.3.2 Materials
•
PC connected to the ASG Guard/ASG Guard Plus via network, Aux, or Modem port.
•
Communication Package (such as Procomm Plus or Telnet session)
C.7.3.3 Procedure for Saving the User Table to the RAM Disk
1.
Log onto the ASG Guard or ASG Guard Plus as a CMaster User.
2. Type in the command CDUMPF and press the ENTER key. You will see the banner ‘--
- Dump Customer Users to File ---‘ and the prompt ‘File Name:’
3. Enter a file name at the “File Name” prompt and press the ENTER key to save the file to the
RAM disk.
4. The transfer will take only a few seconds. To verify the transfer was successful, type ‘VIEW
filename
’ at the system prompt.
Site123>CDUMPF
--- Dump Customer Users to File ---
File Name: USERTAB
; Customer User Table
10
03/02/99 11:26:13 B11B [AUX] CDUMPF Starting
03/02/99 11:26:13 BD3B [AUX] CDUMPF Completed by User: AUX_Default
Site123>
Screen C-9. CDUMPF Command for Saving the User Table as a file on the RAM Disk
Now it is possible to XMODEM or FTP the information to your PC by using the SEND command
to transfer the configuration file. (Refer to the ASG Guard/ASG Guard Plus User’s Guide Section
7.6.6 for detailed information about using the SEND command.) After transferring the file to a
PC, use a word processor program such as Microsoft Word to view the file. To edit the file, first
save the file as a text file in Microsoft Word. Then edit the file using Notepad or Wordpad.
Notepad and Wordpad will not properly display the raw file (as it comes for the ASG Guard/ASG
Guard Plus) since these programs do not recognize the carriage returns without line feeds in the
document.
Содержание Lucent Technologies Access Security Gateway Guard
Страница 12: ...x Page intentionally left blank ...
Страница 28: ...ASG Guard Overview 16 Page intentionally left blank ...
Страница 36: ...Physical Connections 24 Page intentionally left blank ...
Страница 60: ...Modem Port Setup 48 Page intentionally left blank ...
Страница 82: ...Modifying the User Database 70 Page intentionally left blank ...
Страница 106: ...Action and Event Tables 94 ACTION TABLE WORKSHEET Alarm Message or Internal Event Action Routine Routine Parameters ...
Страница 120: ...Action and Event Tables 108 Page intentionally left blank ...
Страница 158: ...User Connectivity 146 Page intentionally left blank ...
Страница 188: ...Log Functions 176 Page intentionally left blank ...
Страница 236: ...Troubleshooting 224 Page intentionally left blank ...
Страница 252: ...Internal Battery Replacement 240 Page intentionally left blank ...
Страница 258: ...Glossary of Command References 246 Page intentionally left blank ...