Action and Event Tables
105
Event
Description
.INTBATOK
Event occurs when the internal battery status has been changed from Low to
OK. For the .INTBATOK event to be generated, the voltage must go from <11
volts to above 11.5 volts.
.LOGFULL
Created by LOGCHECK. Event occurs automatically when the internal Log
Buffer is full.
.MAXRETRY
Generated by PHONHOME, PHIRIS, PHSYSOP, or PAGE according to
Max.Retries system parameter.
.MDMINITERR
Event indicating a modem initialization error.
.MEMLOW
Event occurs on the hour if fewer than 4 KB are available in the ASG
Guard/ASG Guard Plus variable area.
.MONTHLY
Event occurs once a month.
.NETDOWN
Event occurs after a preset length of time during which no network activity is
detected.
.NETUP
Event occurs when network activity is detected following a period of inactivity.
.POWERUP
Event occurs when the system is powered up.
.PPPREQ
Event to trigger the dial-on-demand PPP link.
.POWERLOW
Event indicating that the external power supply has changed from OK to low.
.POWEROK
Event indicating that the external power supply has changed from low to OK.
.RTSHIGH.n
Event indicating that the RS-232 signal RTS has changed from Low to High. (#
indicates host port number)
.RTSLOW.n
Event indicating that the RS-232 signal RTS has changed from High to Low. (#
indicates host port number).
.S#HIGH
Event indicating that the 5 volt sensor has been changed from OK to High.
.S#LOW
Event indicating that the 5 volt sensor has been changed from OK to Low.
.S#OK
Event indicating that the 5 volt sensor has been changed from Low or High to
OK.
.TEMPHIGH
Event occurs when temperature crosses over from an OK condition to a high
temperature condition.
,TEMPLOW
Event occurs when temperature crosses over from an OK condition to a low
temperature condition.
Содержание Lucent Technologies Access Security Gateway Guard
Страница 12: ...x Page intentionally left blank ...
Страница 28: ...ASG Guard Overview 16 Page intentionally left blank ...
Страница 36: ...Physical Connections 24 Page intentionally left blank ...
Страница 60: ...Modem Port Setup 48 Page intentionally left blank ...
Страница 82: ...Modifying the User Database 70 Page intentionally left blank ...
Страница 106: ...Action and Event Tables 94 ACTION TABLE WORKSHEET Alarm Message or Internal Event Action Routine Routine Parameters ...
Страница 120: ...Action and Event Tables 108 Page intentionally left blank ...
Страница 158: ...User Connectivity 146 Page intentionally left blank ...
Страница 188: ...Log Functions 176 Page intentionally left blank ...
Страница 236: ...Troubleshooting 224 Page intentionally left blank ...
Страница 252: ...Internal Battery Replacement 240 Page intentionally left blank ...
Страница 258: ...Glossary of Command References 246 Page intentionally left blank ...