4.2.3 Spare parts list
The
Sentinel LCT8
is a high-accuracy calibrated flow meter. Local custody transfer requirements may disallow field
replacement of any parts in this flow metering system without a proper calibration of the entire system at an approved
calibration facility. Check with local authorities to determine if field replacement of parts is allowed.
If fault is found with the flow meter electronics, the entire measurement head can be replaced to ensure hardware and
firmware compatibility. The replacement part number will be as shown in
Transmitter tag plate on page 4
. To ensure that
the correct part number is ordered, provide your local Panametrics representative with the serial number of the meter, which
is located as shown in
Part string and serial number tag plate on page 4
If it is determined that a flow transducer has been damaged or is faulty, it may also be replaced in the field with no need for
recalibration. Please contact Panametrics for the appropriate part number.
Table 12
below lists the available spare parts for the
Sentinel LCT8
.
Table 12: Available spare parts
Option code
Description
Option code
Description
703-1653-00
SEN898 main PCB assembly
LCT8-SPARE-XDCR-KIT-2MHZ LCT8 transducer kit pair (2MHz)
for 6”-8” flowcells
705-1912-00
SEN898 flow/receiver PCB assembly
LCT8-SPARE-XDCR-KIT-1MHZ LCT8 transducer kit pair (1MHz)
for 10”-24” flowcells
703-1506-03
SEN898 analog input option card (AAR)
LCT8-SPARE-CBL-KIT-6IN
LCT8 cable kit for 6” flowcells
703-1506-04
SEN898 analog input option card (AAA)
LCT8-SPARE-CBL-KIT-8IN
LCT8 cable kit for 8” flowcells
705-1217-01
SEN898 HMI assembly
LCT8-SPARE-CBL-KIT-10IN
LCT8 cable kit for 10” flowcells
705-1246-00
SEN898 AC power supply PCB assembly
LCT8-SPARE-CBL-KIT-12IN
LCT8 cable kit for 12” flowcells
705-1247-00
SEN898 DC power supply PCB assembly
LCT8-SPARE-CBL-KIT-14IN
LCT8 cable kit for 16” flowcells
193-076-14
Fuse AC power supply
LCT8-SPARE-CBL-KIT-16IN
LCT8 cable kit for 18” flowcells
193-076-20
Fuse DC power supply
LCT8-SPARE-CBL-KIT-18IN
LCT8 cable kit for 20” flowcells
SEN_KIT-WAND Magnetic wand with
l screw + washer kit
LCT8-SPARE-CBL-KIT-20IN
LCT8 cable kit for 24” flowcells
412-1906
Stopping plug, ½” NPT
(ATEX, IECEx, FM, CSA) - SS
LCT8-SPARE-CBL-KIT-24IN
LCT8 spare plug kit for
6”-14” flowcells
419-373
Stopping plug, ¾” NPT
(ATEX, IECEx, FM, CSA) - SS
LCT8-SPARE-PLG-KIT-6_14
LCT8 spare plug kit for
16”-24” flowcells
401-083
Pyrogel couplant (4 oz tube)
LCT8-SPARE-PLG-KIT-16_24
LCT8 spare plug kit for
16”-24” flowcells
87
Содержание Panametrics Sentinel LCT8
Страница 1: ...Sentinel LCT8 User s manual...
Страница 2: ...ii...
Страница 4: ...no content intended for this page proceed to next page iv...
Страница 29: ...Figure 32 Wiring LCT8 to SEN898 electronics cross plane 6 24 flowcell local mount ref dwg 702 2041 19...
Страница 30: ...20...
Страница 98: ...88...
Страница 122: ...no content intended for this page 112...
Страница 132: ...122...