4.6.5.3
RS232 and IEEE options
This menu may or may not be present. The exact wording will depend on which (if any)
comms options are fitted. There are no USB or LAN options.
1
RS232 options…
The CTR5000 default settings are the same as the F250’s –
The
RS232 options…
menu is used to set various RS232 parameters. Once set, the menu will
rarely be referred to. The options are described below –
RS232 options
Description
Notes
1 Reset defaults
Resets CTR5000 defaults
Immediately resets to F250 defaults
2 Baud rate (19200)
Select baud rate
1200, 2400, 4800, 9600 or 19200 (default)
3 CTS/RTS (On)
Handshaking on or off
Toggles On (default) or Off
4 Data length
Data length
7 bits or 8 bits (default)
5 Stop bit
Number of stop bits
1 bit or 2 bits (default)
6 Parity
Parity
None (default), Odd or Even
Each RS232 option has its own menu.
ChA ITS90 Pb09 12:02:03
E s c
P g D n
1
2
3
4
5
6
7
8
9
0
6 Parity
1 Reset defaults
2 Baud rate (19200)
3 CTS/RTS (Off)
4 Data length
5 Stop bit
Current settings