oscillator temporization.
4.1.4
Clock fail detector
The clock fail detector (CFD) is designed to respond to HEXT clock failure when the HEXT is used as a
system clock, directly or indirectly. If a failure is detected on the HEXT clock, a clock failure event is sent
to the brake input of TMR1 and TMR8 and an interrupt is generated. This interrupt is directly linked to
CPU NMI so that the software can perform rescue operations. The NMI interrupt keeps executing until
the CFD interrupt pending bit is cleared. This is why the CFD interrupt has to be cleared in the NMI
service routine. The HEXT clock failure will result in a switch of the system clock to the HICK clock, the
CFD to be disabled, HEXT clock to be stopped, and even PLL to be disabled if the HEXT clock is selected
as the system clock through PLL.
4.1.5
Auto step-by-step system clock switch
The automatic frequency switch is designed to ensure a smooth and stable switch of system frequency
when the system clock source is switched from others to the PLL or when the AHB prescaler factor is
changed from large to small. When the operational target is larger than 108 MHz, it is recommended to
enable the automatic frequency switch. Once it is enabled, the AHB bus is halted by hardware till the
completion of the switch. During this switch period, the DMA remain working, and the interrupt events
are recorded and then handled by NVIC when the AHB bus resumes.
4.1.6
Clock output
The microcontroller allows the internal clock signal to be output to external CLKOUT1/2 pins. That is,
ADCCLK, USB48M, SCLK, LICK, LEXT, HICK, HEXT, PLLCLK can be used as CLKOUT1/2 clocks.
When being used as the CLKOUT1/2 clock output pin, the corresponding GPIO port registers must be
configured accordingly.
4.1.7
Interrupts
The microcontroller specifies a stable flag for each clock source. As a result, when a clock source is
enabled, it is possible to determine if the clock is stable by checking the flag pertaining to the clock
source. An interrupt request is generated when the interrupt corresponding to the clock source is enabled.
If a failure is detected on the HEXT clock, the CFD interrupt is generated. Such interrupt is directly linked
to CPU NMI.
4.2 Reset
4.2.1
System reset
AT32F435/437 series provide the following system reset sources:
NRST reset: on the external NRST pin
WDT reset: watchdog overflow
WWDT reset: window watchdog overflow
CPU software reset: Cortex™-M4F software reset
Low-power management reset: This type of reset is enabled when entering Standby mode (by
clearing the nSTDBY_RST bit in the user system data area); this type of reset is also enabled when
entering Deepsleep mode (by clearing the nDEPSLP_RST in the user system data area).
POR reset: power-on reset
LVR reset: low voltage reset
When exiting Standby mode
NRST reset, WDT reset, WWDT reset, software reset and low-power management reset sets all
registers to their reset values except the clock control/status register (CRM_CTRLSTS) and the battery
powered domain; the power-on reset, low-voltage reset or reset generated when exiting Standby mode
sets all registers to their reset values except the battery powered domain registers.