![ARTERY AT32F435 Series Скачать руководство пользователя страница 377](http://html1.mh-extra.com/html/artery/at32f435-series/at32f435-series_reference-manual_2977592377.webp)
AT32F435/437
Series Reference Manual
2022.11.11
Page 377
Rev 2.03
18.6.4 ADC sampling time register 1 (ADC_SPT1)
Accessed by words.
Bit
Register
Reset value
Type
Description
Bit 31: 27 Reserved
0x00
resd
Kept at its default value.
Bit 26: 24 CSPT18
0x0
rw
Sample time selection of channel ADC_IN18
000: 2.5 cycles
001: 6.5 cycles
010: 12.5 cycles
011: 24.5 cycles
100: 47.5 cycles
101: 92.5 cycles
110: 247.5 cycles
111: 640.5 cycles
Bit 23: 21 CSPT17
0x0
rw
Sample time selection of channel ADC_IN17
000: 2.5 cycles
001: 6.5 cycles
010: 12.5 cycles
011: 24.5 cycles
100: 47.5 cycles
101: 92.5 cycles
110: 247.5 cycles
111: 640.5 cycles 111: 239.5 cycles
Bit 20: 18 CSPT16
0x0
rw
Sample time selection of channel ADC_IN16
000: 2.5 cycles
001: 6.5 cycles
010: 12.5 cycles
011: 24.5 cycles
100: 47.5 cycles
101: 92.5 cycles
110: 247.5 cycles
111: 640.5 cycles
Bit 17: 15 CSPT15
0x0
rw
Sample time selection of channel ADC_IN15
000: 2.5 cycles
001: 6.5 cycles
010: 12.5 cycles
011: 24.5 cycles
100: 47.5 cycles
101: 92.5 cycles
110: 247.5 cycles
111: 640.5 cycles
Bit 14: 12 CSPT14
0x0
rw
Sample time selection of channel ADC_IN14
000: 2.5 cycles
001: 6.5 cycles
010: 12.5 cycles
011: 24.5 cycles
100: 47.5 cycles
101: 92.5 cycles
110: 247.5 cycles
111: 640.5 cycles