Mechanical Installation
ANCA Motion
DS619-0-00-0019 - Rev 0
29
4
Following the appropriate lockout procedure, place a sign over the isolation switch clearly indicating to other
personnel that this isolator is not to be touched.
4.4.12
Mounting a Drive
Refer to section
12.7 Dimension Drawings
for drive dimensions and mounting hole
positions.
STEP 1
Drill and tap 2 x M5x0.8P holes to suit hole pattern described in section
12.7 Dimension Drawings.
Overlap the
drive onto the drilled holes to ensure that the hole positions are correct. Ideally the sheet metal panel should be a
minimum 3mm thick.
STEP 2
Fit one of the M5 mounting screws partially into the lower drilled and tapped hole so that the majority of the screw
thread is evident (A).
STEP 3
Position the drive so that the holes with the heat sink line up with the holes in the cabinet. There is an open
slotted hole at the bottom of the heat sink. Insert the drive so that the screw fits within the open slotted hole (B)
for location and then pivot the drive onto the cabinet (C).
STEP 4
Secure the drive to the cabinet by fitting the remaining M5 mount screw into the upper mounting hole to complete
the mounting to the electrical cabinet. Tighten both M5 mounting screws (D & E) to 4~5Nm.
B
C
D
STEP2
STEP 3
STEP 4
A
E
Figure 4-3 Mechanical Mounting of AMD2000 D2003 Servo Drive