AMD2000 Series - Servo Drive - User Manual
28
DS619-0-00-0019 - Rev 0
ANCA Motion
Figure 4-2 Installation in two rows
If armature termination brackets are required to be fitted for EMC compliance, Refer to
6.8.12.1.1
Installation of the EMC Clamp on Shielded Armature Cables,
for fitting instructions.
Refer to
12.6 Environmental Specifications
for further requirements.
4.4
Installation
4.4.11
Power Isolation
DANGER HIGH VOLTAGE - The working DC bus is live at all times when power is on. The Main Isolator
feeding the drive must be switched to the
Off
position at least 15 minutes before any work is commenced
on the unit. The operator must check the bus voltage with a tested working voltage measuring instrument
prior to disconnecting any connectors or opening the DC Bus terminal cover. The red LED indicator on the
front of the drive which indicates that there is charge remaining in the drive is only to be used as an aid to
visual troubleshooting. It shall not be relied on as a means of safety.
It is recommended that the drive is installed with an upstream circuit breaker that is rated appropriately
depending on the model of AMD2000 drive being installed.
Turn the Main Disconnect mains isolator switch to the Off position.