Technical Data
ANCA Motion
DS619-0-00-0019 - Rev 0
175
12
12.16
Standards Conformity
Marking & Applicable
Regulations
Standard
Certification
Organisation
CAT. NO.
D2003-2S1-
A /
AM619-0-03-
0003
D2009-2S1-
A /
AM619-0-03-
0009
LVD
2006/95/EC (Low
Voltage Directive)
EMC 2004/108/EC
(Electromagnetic
Compatibility)
EN 61800-5-1: 2007
(Class I)
EN 61800-3:2004
(Category C3)
Emissions:
CISPR 11:2009/A1:2010
EN 61000-3-
2:2006/A1:2009/A2:2009
EN 61000-3-3:2008
Immunity:
EN 55024:2010
IEC 61000-4-2:2008
IEC 61000-4-
3:2006/A1:2007/A2:2010
IEC 61000-4-4:2004/A1:2010
IEC 61000-4-5:2005
IEC 61000-4-6:2008
IEC 61000-2-4:2003
IEC 60146-1-1:1993
IEC 61000-2-1:1990
Integrity EnE Lab Inc,
Taiwan
Electronics Testing
Center, Taiwan
Report No.
IL110705800
Report
No.
13-01-MAS-
116-R
Report No.
IL100812800
Report
No.
12-06-MAS-
263
16
ETG 1000 series
ETG 9001
ETG 1300
Note: the AMD2000 is a
conforming EtherCAT
device, but does not
qualify as conformance
tested
.
ANCA Motion
self-determination of
compliance.
Those items in the drive
with no applicable
regulation, but to which
standards have been
applied.
Servo profile over EtherCAT fieldbus
profile (SoE). IEC 61800-7.
IEC 61491, for serial data link real
time communications in industrial
machines.
ANCA Motion self-
determination of
compliance within
certain limits.
16
EtherCAT® is a registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany