This document covers through-panel mounting instructions for Unidrive 
M600 / M70X, F300, H300, E200 & E300 Size 4 drives. The standard 
drive is rated to IP20 pollution degree 2 (dry, non-conductive 
contamination only, NEMA 1), however it is possible to configure the 
device to achieve IP65 rating (NEMA 12). This is done by sealing the 
heat sink vent at the rear of the heatsink by installing the high IP insert 
as illustrated in Figure 3-1. Some current derating is required and 
reference should be made to the drive’s User Guide for current derating 
information.

The following items are supplied in the box:

Table 2-1 Contents of the Box (CT Part Number: 3470-0056-01)

The following items are included in the kit box supplied with the 
drive:

Table 2-2 Additional items required

3      Instructions

3.1      Installing the high IP insert

Figure 3-1 Installing the high IP insert

1. To install the high IP insert, firstly place a flat head screwdriver into 

the slot highlighted (1).

2. Pull the hinged baffle up to expose the ventilation hole, install the 

high IP insert into the ventilation hole in the heatsink (2).

3. Ensure the high IP insert is securely installed by firmly pressing it 

into place (3).

4. Close the hinged baffle as shown (1).
To remove the high IP insert, reverse the above instructions.

Unidrive M600-M70X, F300, H300, E200 & E300 

Size 4 Through-panel Mounting Installation Sheet

Follow the instructions

The mechanical and electrical installation instructions must 
be adhered to. Any questions or doubt should be referred to 
the supplier of the equipment. It is the responsibility of the 
owner or user to ensure that the installation of the drive and 
any external option unit, and the way in which they are 
operated and maintained, comply with the requirements of 
the Health and Safety at Work Act in the United Kingdom or 
applicable legislation and regulations and codes of practice in 
the country in which the equipment is used.

Competence of the installer

The drive must be installed by professional assemblers who 
are familiar with the requirements for safety and EMC. The 
assembler is responsible for ensuring that the end product or 
system complies with all the relevant laws in the country 
where it is to be used.

Description

Image

Qty

Through panel mounting gasket

x 1

Through panel securing brackets 

x 2

High IP insert

x 1

Through panel mounting 
instructions sheet

x 1

Description

Image

Qty

Frame 4 mounting brackets

x 2

WARNING