Fault Tracing
ANCA Motion
DS619-0-00-0019 - Rev 0
149
11
2. Encoder cable is disconnected.
3. Encoder cable is wired incorrectly.
4. Encoder is not analogue.
5. Encoder is not outputting the correct voltage.
6. Encoder is faulty.
7. Drive is faulty. Please contact ANCA Motion for support.
Severity
Error
Encoder Amplitude High - External
E0028
Description
The magnitude of the signals coming from the external analogue encoder is too high. Possible
causes for this error are:
1. Encoder cable is wired incorrectly.
2. Encoder is not analogue.
3. Encoder is not outputting the correct voltage.
4. Encoder is faulty.
5. Drive is faulty. Please contact ANCA Motion for support.
Severity
Error
Excess Difference in Position Feedback
E0033
Description
The difference between motor and external feedback is greater than the configured threshold.
Possible causes for this error are:
1. Incorrect encoder line count.
2. Incorrect gear box ratio and/or feed constant.
3. Faulty drive mechanism (eg. loss coupling).
4. Faulty encoder.
5. Fault drive. Please contact ANCA Motion for support.
Severity
Error
Variable Torque Limit Error
E0080
Description
Configuration of the variable torque limit is invalid. The minimum torque limit is configured
larger than the maximum torque limit.
Severity
Error
Drive Not Configured
E0100
Description
The drive has been enabled before being configured
Severity
Error
Amplifier Temperature Sensor Error - High
E0101
Description
Drive power stage temperature sensor is reading a value higher than the drive's sensor
operating range. Drive is faulty. Please contact ANCA Motion for support.
Severity
Error
Amplifier Temperature Sensor Error - Low
E0102
Description
Drive power stage temperature sensor is reading a value lower than the drive's sensor
operating range. Drive is faulty. Please contact ANCA Motion for support.
Severity
Error
Amplifier Temperature High Warning
W0103
Description
The drive amplifier (power stage) temperature exceeds the hardware's warning level. Possible
causes for this error are:
1. Operating environment is outside specification.
2. Drive ventilation is insufficient.